Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jan;5(1):277-281.
doi: 10.3892/etm.2012.740. Epub 2012 Oct 10.

Visual performance of Acrysof ReSTOR compared with a monofocal intraocular lens following implantation in cataract surgery

Affiliations

Visual performance of Acrysof ReSTOR compared with a monofocal intraocular lens following implantation in cataract surgery

Jing Ji et al. Exp Ther Med. 2013 Jan.

Abstract

The aim of this study was to compare the visual performance of Acrysof ReSTOR and Acrysof Natural intraocular lenses (IOLs) following cataract surgery. A randomized prospective study was performed in which 64 eyes (51 patients) were divided randomly into two groups. Monofocal IOLs (Acrysof Natural) were implanted into 34 eyes (27 patients) and multifocal IOLs (Acrysof ReSTOR) were implanted into 30 eyes (24 patients) using phacoemulsification surgery. The corrected distance visual acuity, near visual acuity, pseudoaccommodation, contrast sensitivity (CS) and wavefront analysis were measured at 1 week, 1 month and 3 months after surgery. The distance vision of the monofocal and ReSTOR patients improved equally with glasses (P<0.05). A greater improvement in near vision without glasses was observed in the ReSTOR-implanted patients (P<0.01). The CS values of the multifocal IOL group were significantly lower than those of the monofocal IOL group for all spatial frequencies tested (P<0.05). The spherical aberration was significantly higher in the multifocal IOL group compared with the monofocal IOL group (P<0.05). We observed no differences in coma between the two groups. The difference in the amplitude of pseudoaccommodation between the two groups was statistically significant (-3.14±0.91 D in the ReSTOR group vs. -1.03±0.33 D in the Natural group, P<0.01). The improvement in near vision was significantly more evident in the ReSTOR patients. Compared with the monofocal IOL lens, the multifocal lens is able to increase the amplitude of pseudoaccommodation. However, increased spherical aberration may contribute to lower CS values in the multifocal IOL group.

PubMed Disclaimer

References

    1. Javitt JC, Steinert RF. Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes. Ophthalmology. 2000;107:2040–2048. - PubMed
    1. Elliott DB. Evaluating visual function in cataract. Optom Vision Sci. 1993;70:896–902. - PubMed
    1. Dick HB, Krummenauer F, Schwenn O, Krist R, Pfeiffer N. Objective and subjective evaluation of photic phenemena after monofocal and multifocal intraocular lens implantation. Ophthamology. 1999;106:1878–1886. - PubMed
    1. Yoon G, Macrae S, Williams DR, Cox IG. Causes of spherical aberration induced by laser refractive surgery. J Cataract Refract Surg. 2005;31:127–135. - PubMed
    1. Zhao YE, Li JH, Zhu J, Wang DD, Wang QM. Evaluation of long term visual performance following AcrySof ReSTOR lens implantation. Chin Med J (Engl) 2009;122:2705–2710. - PubMed

LinkOut - more resources