. 2013 Feb 5;85(3):1896-904.
doi: 10.1021/ac303188j. Epub 2013 Jan 14.

Development and validation of the first liquid chromatography-tandem mass spectrometry assay for simultaneous quantification of multiple antiretrovirals in meconium

Collaborators, Affiliations

Development and validation of the first liquid chromatography-tandem mass spectrometry assay for simultaneous quantification of multiple antiretrovirals in meconium

Sarah K Himes et al. Anal Chem. .

Abstract

A novel method for the simultaneous quantification of 16 antiretroviral (ARV) drugs and 4 metabolites in meconium was developed and validated. Quantification of 6 nucleoside/nucleotide reverse transcriptase inhibitors, 2 non-nucleoside reverse transcriptase inhibitors, 7 protease inhibitors, and 1 integrase inhibitor was achieved in 0.25 g of meconium. Specimen preparation included methanol homogenization and solid-phase extraction. Separate positive and negative polarity multiple reaction monitoring mode injections were required to achieve sufficient sensitivity. Linearity ranged from 10 to 75 ng/g up to 2500 ng/g for most analytes and 100-500 ng/g up to 25,000 ng/g for some; all correlation coefficients were ≥0.99. Extraction efficiencies from meconium were 32.8-119.5% with analytical recovery of 80.3-108.3% and total imprecision of 2.2-11.0% for all quantitative analytes. Two analytes with analytical recovery (70.0-138.5%) falling outside the 80-120% criteria range were considered semiquantitative. Matrix effects were -98.3-47.0% and -98.0-67.2% for analytes and internal standards, respectively. Analytes were stable (>75%) at room temperature for 24 h, 4 °C for 3 days, -20 °C for 3 freeze-thaw cycles over 3 days, and on the autosampler. Method applicability was demonstrated by analyzing meconium from HIV-uninfected infants born to HIV-positive mothers on ARV therapy. This method can be used as a tool to investigate the potential effects of in utero ARV exposure on childhood health and neurodevelopmental outcomes.

PubMed Disclaimer

Figures

Figure 1
Figure 1
MRM chromatograms of a) extracted blank meconium, b) ARV limits of quantification, and c) ARVs detected in authentic meconium specimens from ARV-exposed, HIV-uninfected infants.

References

    1. World Health Organization. Towards universal access. Progress report 2010. Available at http://www.who.int/hiv/pub/2010progressreport/en/index.html.
    1. Whitmore SK, Zhang X, Taylor AW, Blair JM. J Acquir Immune Defic Syndr. 2011;57:218–222. - PubMed
    1. Panel on Treatment of HIV-Infected Pregnant Women and Prevention of Perinatal Transmission. Recommendations for Use of Antiretroviral Drugs in Pregnant HIV-1-Infected Women for Maternal Health and Interventions to Reduce Perinatal HIV Transmission in the United States (Updated July 2012). Department of Health and Human Services. Available at http://aidsinfo.nih.gov/contentfiles/lvguidelines/perinatalgl.pdf.
    1. Barret B, Tardieu M, Rustin P, Lacroix C, Chabrol B, Desguerre I, Dollfus C, Mayaux MJ, Blanche S. AIDS. 2003;17:1769–1785. - PubMed
    1. Castillo AB, Tarantal AF, Watnik MR, Martin RB. J Orthop Res. 2002;20:1185–1189. - PubMed

Publication types

MeSH terms

Substances