Cardiac MRI: a new gold standard for ventricular volume quantification during high-intensity exercise
- PMID: 23258478
- DOI: 10.1161/CIRCIMAGING.112.980037
Cardiac MRI: a new gold standard for ventricular volume quantification during high-intensity exercise
Abstract
Background: Accurate measures are critical when attempting to distinguish normal from pathological changes in cardiac function during exercise, yet imaging modalities have seldom been assessed against invasive exercise standards. We sought to validate a novel method of biventricular volume quantification by cardiac MRI (CMR) during maximal exercise.
Methods and results: CMR was performed on 34 subjects during exercise and free-breathing with the use of an ungated real-time (RT-ungated) CMR sequence. ECG and respiratory movements were retrospectively synchronized, enabling compensation for cardiac cycle and respiratory phase. Feasibility of RT-ungated imaging was compared with standard exercise CMR imaging with ECG gating (gated); accuracy of RT-ungated CMR was assessed against an invasive standard (direct Fick); and reproducibility was determined after a second bout of maximal exercise. Ventricular volumes were analyzed more frequently during high-intensity exercise with RT-ungated compared with gated CMR (100% versus 47%; P<0.0001) and with better interobserver variability for RT-ungated (coefficient of variation=1.9% and 2.0% for left and right ventricular stroke volumes, respectively) than gated (coefficient of variation=15.2% and 13.6%; P<0.01). Cardiac output determined by RT-ungated CMR proved accurate against the direct Fick method with excellent agreement (intraclass correlation coefficient, R=0.96), which was highly reproducible during a second bout of maximal exercise (R=0.98).
Conclusions: When RT-ungated CMR is combined with post hoc analysis incorporating compensation for respiratory motion, highly reproducible and accurate biventricular volumes can be measured during maximal exercise.
Comment in
-
Letter by Yoneyama and Akashi regarding article, "Cardiac magnetic resonance imaging: a new gold standard for ventricular volume quantification during high-intensity exercise".Circ Cardiovasc Imaging. 2013 May 1;6(3):e19. doi: 10.1161/CIRCIMAGING.113.000214. Circ Cardiovasc Imaging. 2013. PMID: 23696590 No abstract available.
-
Response to letter regarding article, "Cardiac magnetic resonance imaging: a new gold standard for ventricular volume quantification during high-intensity exercise".Circ Cardiovasc Imaging. 2013 May 1;6(3):e20. doi: 10.1161/CIRCIMAGING.113.000389. Circ Cardiovasc Imaging. 2013. PMID: 23696591 No abstract available.
Similar articles
-
Response to letter regarding article, "Cardiac magnetic resonance imaging: a new gold standard for ventricular volume quantification during high-intensity exercise".Circ Cardiovasc Imaging. 2013 May 1;6(3):e20. doi: 10.1161/CIRCIMAGING.113.000389. Circ Cardiovasc Imaging. 2013. PMID: 23696591 No abstract available.
-
Letter by Yoneyama and Akashi regarding article, "Cardiac magnetic resonance imaging: a new gold standard for ventricular volume quantification during high-intensity exercise".Circ Cardiovasc Imaging. 2013 May 1;6(3):e19. doi: 10.1161/CIRCIMAGING.113.000214. Circ Cardiovasc Imaging. 2013. PMID: 23696590 No abstract available.
-
Intra-observer and interobserver variability of biventricular function, volumes and mass in patients with congenital heart disease measured by CMR imaging.Int J Cardiovasc Imaging. 2010 Jan;26(1):57-64. doi: 10.1007/s10554-009-9501-y. Epub 2009 Sep 16. Int J Cardiovasc Imaging. 2010. PMID: 19757150 Free PMC article.
-
Exercise cardiac magnetic resonance imaging: a feasibility study and meta-analysis.Am J Physiol Regul Integr Comp Physiol. 2018 Oct 1;315(4):R638-R645. doi: 10.1152/ajpregu.00158.2018. Epub 2018 Jun 27. Am J Physiol Regul Integr Comp Physiol. 2018. PMID: 29949409 Free PMC article. Review.
-
Cardiac Magnetic Resonance Normal Reference Values of Biventricular Size and Function in Male Athlete's Heart.JACC Cardiovasc Imaging. 2019 Sep;12(9):1755-1765. doi: 10.1016/j.jcmg.2018.09.021. Epub 2018 Dec 12. JACC Cardiovasc Imaging. 2019. PMID: 30553678
Cited by
-
Exercise cardiac magnetic resonance imaging to assess dynamic right ventricular outflow tract obstruction in congenital heart disease: a case report.Eur Heart J Case Rep. 2020 Dec 15;5(1):ytaa431. doi: 10.1093/ehjcr/ytaa431. eCollection 2021 Jan. Eur Heart J Case Rep. 2020. PMID: 33644642 Free PMC article.
-
Endurance exercise and the risk of cardiovascular pathology in men: a comparison between lifelong and late-onset endurance training and a non-athletic lifestyle - rationale and design of the Master@Heart study, a prospective cohort trial.BMJ Open Sport Exerc Med. 2021 Apr 16;7(2):e001048. doi: 10.1136/bmjsem-2021-001048. eCollection 2021. BMJ Open Sport Exerc Med. 2021. PMID: 33927885 Free PMC article.
-
Compact MR-compatible ergometer and its application in cardiac MR under exercise stress: A preliminary study.Magn Reson Med. 2022 Oct;88(4):1927-1936. doi: 10.1002/mrm.29311. Epub 2022 Jun 1. Magn Reson Med. 2022. PMID: 35649186 Free PMC article.
-
Exercise capacity in diabetes mellitus is predicted by activity status and cardiac size rather than cardiac function: a case control study.Cardiovasc Diabetol. 2018 Mar 23;17(1):44. doi: 10.1186/s12933-018-0688-x. Cardiovasc Diabetol. 2018. PMID: 29571290 Free PMC article.
-
Cardiovascular Magnetic Resonance and Sport Cardiology: a Growing Role in Clinical Dilemmas.J Cardiovasc Transl Res. 2020 Jun;13(3):296-305. doi: 10.1007/s12265-020-10022-7. Epub 2020 May 20. J Cardiovasc Transl Res. 2020. PMID: 32436168 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical