Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Mar-Apr;19(2):165-72.
doi: 10.4261/1305-3825.DIR.6197-12.1.

Coil embolization in 481 ruptured intracranial aneurysms: angiographic and clinical results

Affiliations
Free article

Coil embolization in 481 ruptured intracranial aneurysms: angiographic and clinical results

Hasan Dinç et al. Diagn Interv Radiol. 2013 Mar-Apr.
Free article

Abstract

Purpose: We aimed to report our 13-year experience with the embolization of ruptured cerebral aneurysms using detachable coils and postembolization angiographic and clinical results.

Materials and methods: Between June 1998 and September 2011, 481 patients with ruptured aneurysms were referred for endovascular treatment with detachable coils at our center. The technical feasibility, procedural complications, morbidity, mortality, and initial angiographic and clinical results were evaluated.

Results: Endovascular treatment was successful in 95.6% of the patients. Postembolization angiography showed complete occlusion in 63.4%, a neck remnant in 30.8%, and incomplete occlusion in 5.8% of the aneurysms. A total of 331 patients were followed up. The overall angiographic results showed stable occlusion in 234 aneurysms (70.7%) and recurrence in 97 aneurysms (29.3%). During the follow-up period, stable angiographic occlusion was evident in 75% of the small, 61% of the large, and 38.5% of the giant aneurysms. Complications during the coiling procedure occurred in 75 procedures (15.6%). Ischemic complications were observed in 33 procedures (6.9%), and perforation of the aneurysm during the coiling occurred in 12 cases (2.5%). Five (41.7%) of 12 patients who had perforation during coiling died. The overall procedure-related morbidity and mortality were 5.6% and 2%, respectively. During the follow-up period, two patients (0.4%) had early rebleeding. None of the patients showed late rebleeding. In the follow-up, the retreatment rate was 12.6%.

Conclusion: Our data confirm the feasibility, safety, and efficacy of endovascular coil embolization in patients with ruptured cerebral aneurysms.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources