. 2012 Winter;12(4):363-6.

Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery: is it worth the cost?

Affiliations

Intraoperative recurrent laryngeal nerve monitoring in thyroid surgery: is it worth the cost?

Grayson Gremillion et al. Ochsner J. 2012 Winter.

Abstract

Background: Intraoperative nerve monitoring (IONM) has been used in head and neck surgery since the 1970s. Its utilization for monitoring and protecting the recurrent laryngeal nerve, however, is a controversial subject. This paper details the use, value, and cost of this technology within a single institution.

Methods: We conducted a retrospective chart review, analysis of surgery time with and without IONM, analysis of postoperative vocal cord function, and review of the literature.

Results: IONM did not reduce the operative time during either thyroid lobectomies or total thyroidectomies in 119 surgeries. Use of IONM increased the cost of each surgery by $387. IONM did not decrease the number of injured nerves (postoperative paresis).

Conclusions: IONM has proven to be highly useful in certain circumstances but has not been definitively proven to protect the nerve any more effectively than the gold standard of nerve visualization. In our study, the use of IONM did not reduce the time of thyroid surgery and did increase the cost. While IONM may, in special clinical circumstances such as revision and malignant thyroid surgery, increase the value of the operation, its use for every thyroid surgery does not appear to be cost effective or valuable to the patient.

Keywords: Head and neck surgery; Nerve Integrity Monitor tube; intraoperative nerve monitoring; recurrent laryngeal nerve; thyroid; vocal cord paralysis.

PubMed Disclaimer

Conflict of interest statement

The authors have no financial or proprietary interest in the subject matter of this article.

Similar articles

Cited by

References

    1. Riddell VH. Injury to recurrent laryngeal nerves during thyroidectomy; a comparison between the results of identification and non-identification in 1022 nerves exposed to risk. Lancet. 1956 Sep 29;271(6944):638–641. - PubMed
    1. Miller MC, Spiegel JR. Identification and monitoring of the recurrent laryngeal nerve during thyroidectomy. Surg Oncol Clin N Am. 2008 Jan;17(1):121–144. - PubMed
    1. Feinstein B. The application of electromyography to affections of the facial and the intrinsic laryngeal muscles. Proc R Soc Med. 1946 Oct;39(12):817–819. - PMC - PubMed
    1. Delgado TE, Bucheit WA, Rosenholtz HR, Chrissian S. Intraoperative monitoring of facila muscle evoked responses obtained by intracranial stimulation of the facila nerve: a more accurate technique for facila nerve dissection. Neurosurgery. 1979 May;4(5):418–421. - PubMed
    1. Brennan J, Moore EJ, Shuler KJ. Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy, and parotidectomy. Otolaryngol Head Neck Surg. 2001 May;124(5):537–543. - PubMed

LinkOut - more resources