Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Aug;41(6):552-60.
doi: 10.1111/ceo.12058.

Efficacy and safety of collagen matrix implants in phacotrabeculectomy and comparison with mitomycin C augmented phacotrabeculectomy at 1 year

Affiliations
Comparative Study

Efficacy and safety of collagen matrix implants in phacotrabeculectomy and comparison with mitomycin C augmented phacotrabeculectomy at 1 year

Arun Narayanaswamy et al. Clin Exp Ophthalmol. 2013 Aug.

Abstract

Background: To assess the efficacy and safety of collagen matrix implant (Ologen) in phacotrabeculectomy.

Design: Prospective, non-randomized, comparative study.

Participants: Sixty-six Asian patients.

Methods: Thirty three consecutive patients underwent phacotrabeculectomy with Ologen implant and intraocular lens implantation, and 33 subjects recruited as controls underwent surgery with mitomycin C augmentation.

Main outcome measures: The primary outcome measure was postoperative intraocular pressure at month 12. Additional postoperative treatments, such as bleb needling, and adverse events were secondary outcomes.

Results: The overall percentage reduction in intraocular pressure was 13% (95% confidence interval 6.7-19.2) in the Ologen group and 26% (95% confidence interval 14.8-37.9) in the mitomycin C group (P = 0.05). At 1 year after surgery (after adjusting for baseline differences), intraocular pressure decreased by 4.2 mmHg (95% confidence interval 2.8-5.6 mmHg) and 5.6 mmHg (95% confidence interval 4.2-7.0 mmHg), respectively (P = 0.16). Needling with 5-fluorouracil was required more often in the Ologen group (39% vs. 6%; P = 0.003). There was similar frequency (<10%) of adverse events in both groups, and there were no complications directly related to the Ologen implant. The blebs in the mitomycin C group had greater central area (P = 0.005), maximal area (P = 0.01) and height (P = 0.005), and were less vascular (P = 0.023) than the Ologen blebs.

Conclusions: At 1 year, the overall performance of Ologen in combined phacotrabeculectomy was suboptimal compared with combined surgery with mitomycin C. Eyes in the Ologen group required more frequent bleb needling procedures.

Keywords: Ologen; collagen implant; glaucoma surgery; wound healing.