. 2013 Feb;14(2):e77-84.
doi: 10.1097/PCC.0b013e31827127e4.

Variability in anticoagulation management of patients on extracorporeal membrane oxygenation: an international survey

Affiliations

Variability in anticoagulation management of patients on extracorporeal membrane oxygenation: an international survey

Melania M Bembea et al. Pediatr Crit Care Med. 2013 Feb.

Abstract

Objective: The objective of this study was to determine current practices of anticoagulation in patients on extracorporeal membrane oxygenation.

Design: Internet-based cross-sectional survey distributed between November 2010 and May 2011.

Setting: Extracorporeal Life Support Organization-registered extracorporeal membrane oxygenation centers internationally.

Participants: : Extracorporeal membrane oxy genation medical directors and coordinators.

Interventions: None.

Measurements and main results: There were 121 responses from extracorporeal membrane oxy genation medical directors and coordinators at 187 Extracorporeal Life Support Organization centers with access to the survey. Eighty-four of 117 (72%) respondents reported having a written institutional extracorporeal membrane oxy genation protocol for both anticoagulation and blood product management at their institutions. Sixty-nine of 117 (59%) respondents reported use of tip-to-tip or partially heparin-bonded circuits. Unfractionated heparin was used at all centers; only 8% of respondents indicated use of alternative anticoagulation medications in the six months prior to the survey. The preferred method of anticoagulation monitoring was the serial measurement of activated clotting time, as reported by 97% of respondents. In this survey, 82% of respondents reported antithrombin III testing, 65% reported anti-factor Xa testing, and 43% reported use of thromboelastography during extracorporeal membrane oxy genation. Goal ranges for these three tests and interventions triggered by out-of-range values were found to be variable.

Conclusions: Extracorporeal membrane oxy genation anticoagulation management policies vary widely by center. The majority of extracorporeal membrane oxy genation programs employ activated clotting time as the preferred anticoagulation monitoring tool. The coagulation system is also monitored using more specific markers such as antithrombin III, anti-factor Xa, and thromboelastography by a large number of centers. Future research is needed to elucidate optimal anticoagulation management and improve outcomes.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest

The authors have no conflicts of interest relevant to this article.

Comment in

References

    1. Muntean W. Coagulation and anticoagulation in extracorporeal membrane oxygenation. Artif Organs. 1999;23:979–983. - PubMed
    1. Oliver WC. Anticoagulation and coagulation management for ECMO. Semin Cardiothorac Vasc Anesth. 2009;13:154–175. - PubMed
    1. Conrad SA, Rycus PT, Dalton H. Extracorporeal life support registry report 2004. ASAIO J. 2005;51:4–10. - PubMed
    1. Lawson DS, Lawson AF, Walczak R, et al. North american neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of extracorporeal life support organization (ELSO) centers. J Extra Corpor Technol. 2008;40:166–174. - PMC - PubMed
    1. Graves DF, Chernin JM, Kurusz M, et al. Anticoagulation practices during neonatal extracorporeal membrane oxygenation: Survey results. Perfusion. 1996;11:461–466. - PubMed

Publication types