Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Feb;17(1):21-30.
doi: 10.1007/s10029-012-1037-8. Epub 2013 Jan 8.

A critical review of biologic mesh use in ventral hernia repairs under contaminated conditions

Affiliations

A critical review of biologic mesh use in ventral hernia repairs under contaminated conditions

F E Primus et al. Hernia. 2013 Feb.

Abstract

Purpose: We used an evidence-based approach to determine whether the promotions and claims of superiority of biologic mesh over synthetic mesh use in ventral hernia repairs (VHRs) under contaminated conditions were sound and valid.

Methods: We searched the Medline database to specifically identify review articles relating to biologic mesh and VHR and critically reviewed these studies using an evidence-based approach.

Results: For the past 45 years, four clinical reviews and one systematic review have included biologic meshes as part of a larger discussion on available prosthetics for VHR. All reviews supported biologic mesh use, especially in the setting of contaminated fields. Yet, the primary literature included in these reviews and served as the basis for these conclusions consisted entirely of case series and case reports, which have the lowest level of evidence in determining scientific validity. Furthermore, the FDA has neither cleared nor approved this particular use.

Conclusions: The cumulative data regarding biologic mesh use in VHRs under contaminated conditions does not support the claim that it is better than synthetic mesh used under the same conditions. The highly promoted and at least moderately utilized practice of placing biologic mesh in contamination is being done outside of the original intended use, and a re-evaluation of or possible moratorium on biologic mesh use in hernia surgery is seriously warranted. Alternatively, an industry-sponsored national registry of patients in whom ventral hernia repairs involved biologic mesh would substantively add to our understanding regarding how these intriguing biomaterials are being used and their overall clinical efficacy.

PubMed Disclaimer

Comment in

References

    1. Shankaran V, Weber DJ, Reed RL, II, Luchette FA. A review of available prosthetics for ventral hernia repair. Ann Surg. 2011;253(1):16–26. doi: 10.1097/SLA.0b013e3181f9b6e6. - DOI - PubMed
    1. Gray SH, Hawn MT, Itani KM. Surgical progress in inguinal and ventral incisional hernia repair. Surg Clin North Am. 2008;88(1):17–26. vii. doi: 10.1016/j.suc.2007.11.007.S0039-6109(07)00177-6 - DOI - PubMed
    1. Basoglu M, Yildirgan MI, Yilmaz I, Balik A, Celebi F, Atamanalp SS, Polat KY, Oren D. Late complications of incisional hernias following prosthetic mesh repair. Acta Chir Belg. 2004;104(4):425–428. - PubMed
    1. Morris-Stiff GJ, Hughes LE. The outcomes of nonabsorbable mesh placed within the abdominal cavity: literature review and clinical experience. J Am Coll Surg. 1998;186(3):352–367.S1072-7515(98)00002-7 - PubMed
    1. Hiles M, Record Ritchie RD, Altizer AM. Are Biologic Grafts Effective for Hernia Repair. Surgical Innovation. 2009;16(1):26–37. - PubMed

Publication types

MeSH terms