Impact of organ-specific dose reduction on the image quality of head and neck CT angiography
- PMID: 23300039
- DOI: 10.1007/s00330-012-2750-5
Impact of organ-specific dose reduction on the image quality of head and neck CT angiography
Abstract
Objectives: Organ-specific dose reduction (OSDR) algorithms can reduce radiation on radiosensitive organs up to 59 %. This study evaluates the influence of a new OSDR algorithm on image quality of head and neck computed tomographic angiography (CTA) in clinical routine.
Methods: Sixty-two consecutive patients (68 ± 13 years) were randomised into two groups and imaged using 128-row multidetector CT. Group A (n = 31) underwent conventional CTA and group B (n = 31) CTA with a novel OSDR algorithm. Subjective and objective image quality were statistically compared. Subjective image quality was rated on a five-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated with region-of-interest measurements.
Results: The SNR of the common carotid artery and middle cerebral artery was 53.6 ± 22.7 and 43.3 ± 15.3 (group A) versus 54.1 ± 20.5 and 46.2 ± 14.6 (group B). The CNR was 40.0 ± 19.3 and 29.7 ± 12.0 (group A) compared with 40.7 ± 16.8 and 32.9 ± 10.9 (group B), respectively. Subjective image quality was excellent in both groups (mean score 4.4 ± 0.7 versus 4.4 ± 0.6). Differences between the two groups were not significant.
Conclusions: The novel OSDR algorithm does not compromise image quality of head and neck CTA. Its application can be recommended for CTA in clinical routine to protect the thyroid gland and ocular lenses from unnecessary high radiation.
Key points: • Organ-specific dose reduction (OSDR) can significantly reduce radiation exposure during CT • OSDR does not compromise image quality of head and neck CTA • OSDR can significantly lower the risk of radiation damage to sensitive organs • OSDR can easily be applied in routine clinical practice.
Similar articles
-
Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography.Eur Radiol. 2015 May;25(5):1453-63. doi: 10.1007/s00330-014-3533-y. Epub 2015 Jan 31. Eur Radiol. 2015. PMID: 25636415 Clinical Trial.
-
Low-Dose Computed Tomography With Adaptive Statistical Iterative Reconstruction and Low Tube Voltage in Craniocervical Computed Tomographic Angiography: Impact of Body Mass Index.J Comput Assist Tomogr. 2015 Sep-Oct;39(5):774-80. doi: 10.1097/RCT.0000000000000260. J Comput Assist Tomogr. 2015. PMID: 25938211
-
Cerebral computed tomographic angiography using third-generation reconstruction algorithm provides improved image quality with lower contrast and radiation dose.Neuroradiology. 2020 Aug;62(8):965-970. doi: 10.1007/s00234-020-02406-y. Epub 2020 Apr 10. Neuroradiology. 2020. PMID: 32277245
-
Assessment of radiation dose and iodine load reduction in head-neck CT angiography using two scan protocols with wide-detector.J Xray Sci Technol. 2019;27(5):981-993. doi: 10.3233/XST-190541. J Xray Sci Technol. 2019. PMID: 31450541
-
Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods.Acta Radiol. 2022 Oct;63(10):1353-1362. doi: 10.1177/02841851211041813. Epub 2021 Oct 14. Acta Radiol. 2022. PMID: 34647842
Cited by
-
Application of bolus tracking: The effect of ROI positions on the images quality of cervicocerebral CT angiography.Heliyon. 2024 Apr 4;10(7):e29260. doi: 10.1016/j.heliyon.2024.e29260. eCollection 2024 Apr 15. Heliyon. 2024. PMID: 38617933 Free PMC article.
-
Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography.Pediatr Radiol. 2014 Sep;44(9):1065-9. doi: 10.1007/s00247-014-2950-z. Epub 2014 Mar 29. Pediatr Radiol. 2014. PMID: 25022489
-
Impact of increasing levels of adaptive statistical iterative reconstruction on image quality in oil-based postmortem CT angiography in coronary arteries.Int J Legal Med. 2021 Sep;135(5):1869-1878. doi: 10.1007/s00414-021-02530-1. Epub 2021 Feb 24. Int J Legal Med. 2021. PMID: 33629138 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical