Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 May 15;61(1):18-22.
doi: 10.1016/j.ymeth.2012.12.015. Epub 2013 Jan 7.

Cytokine measurements and possible interference from heterophilic antibodies--problems and solutions experienced with rheumatoid factor

Affiliations

Cytokine measurements and possible interference from heterophilic antibodies--problems and solutions experienced with rheumatoid factor

Else Marie Bartels et al. Methods. .

Abstract

Cytokines are important in the understanding of the immune process in health and disease and are valuable indicators in diagnostics. Measurements of cytokines are based on immunometric methods, and it is important to understand possible pitfalls in these methods to produce reliable cytokine data. This paper focuses on obtaining optimal measurements when applying enzyme-linked immunosorbent assay (ELISA) or multiplex immunoassays (MIA). Cytokines are measured in serum or plasma, as well as in various other body fluids, all containing a series of antibodies and the possibility of interference from these. Some antibodies, such as heterophilic and human anti-animal antibodies, are able to interfere with all immunoassays, but the immunometric techniques are most prone to serious interference from this source. Another type, rheumatoid factor (RF) is a composite of different autoimmune antibodies which can be present in both blood and synovial fluid. RF is present in some arthritic diseases as well as in some other medical conditions. When present, especially RF IgM is known to interfere with the immunometric measurements. A possible and affordable solution to diminish this interference is PEG precipitation, but other efficient, but more expensive, methods, such as precipitation using Protein L or commercially available blocking agents, are also available. Interference of RF is at present not tested in all cytokine assays, but degree of interference from RF, human anti-animal and heterophilic antibodies, as well as from other possible disease-specific antibodies, must always be considered when developing and applying new assays for cytokine measurements.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources