Detection of breast cancer with a computer-aided detection applied to full-field digital mammography
- PMID: 23319110
- PMCID: PMC3705026
- DOI: 10.1007/s10278-012-9564-5
Detection of breast cancer with a computer-aided detection applied to full-field digital mammography
Abstract
A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, mammographic presentation, lesion size, and results of histopathological examination. The overall sensitivity of CAD was 91 % (139 of 152 cases). CAD detected 100 % (47/47) of cancers manifested as microcalcifications; 98 % (62/63) of those manifested as non-calcified masses; 100 % (15/15) of those manifested as mixed masses and microcalcifications; 75 % (12/16) of those manifested as architectural distortions, and 69 % (18/26) of those manifested as focal asymmetry. CAD sensitivity was 83 % (10/12) for cancers measuring 1-10 mm, 92 % (37/40) for those measuring 11-20 mm, and 92 % (92/100) for those measuring >20 mm. There was no significant difference in CAD detection efficiency between cancers in dense breasts (88 %; 69/78) and those in non-dense breasts (95 %; 70/74). CAD showed a high sensitivity of 91 % (139/152) for the mammographic appearance of cancer and 100 % sensitivity for identifying cancers manifested as microcalcifications. Sensitivity was not influenced by breast density or lesion size. CAD should be effective for helping radiologists detect breast cancer at an earlier stage.
Similar articles
-
Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers.Eur J Radiol. 2011 Mar;77(3):457-61. doi: 10.1016/j.ejrad.2009.08.024. Epub 2009 Oct 28. Eur J Radiol. 2011. PMID: 19875260
-
Detection of breast cancer with full-field digital mammography and computer-aided detection.AJR Am J Roentgenol. 2009 Feb;192(2):337-40. doi: 10.2214/AJR.07.3884. AJR Am J Roentgenol. 2009. PMID: 19155392
-
[Impact of breast density on computer-aided detection (CAD) of breast cancer].Zhonghua Zhong Liu Za Zhi. 2012 May;34(5):360-3. doi: 10. 3760/cma.j.issn.0253-3766.2012.05.009. Zhonghua Zhong Liu Za Zhi. 2012. PMID: 22883457 Chinese.
-
CADx of mammographic masses and clustered microcalcifications: a review.Med Phys. 2009 Jun;36(6):2052-68. doi: 10.1118/1.3121511. Med Phys. 2009. PMID: 19610294 Review.
-
Detection of potential microcalcification clusters using multivendor for-presentation digital mammograms for short-term breast cancer risk estimation.Med Phys. 2019 Apr;46(4):1938-1946. doi: 10.1002/mp.13450. Epub 2019 Mar 7. Med Phys. 2019. PMID: 30801718 Free PMC article. Review.
Cited by
-
Improving mammography interpretation for both novice and experienced readers: a comparative study of two commercial artificial intelligence software.Eur Radiol. 2024 Jun;34(6):3924-3934. doi: 10.1007/s00330-023-10422-8. Epub 2023 Nov 8. Eur Radiol. 2024. PMID: 37938383
-
Radiomics: from qualitative to quantitative imaging.Br J Radiol. 2020 Apr;93(1108):20190948. doi: 10.1259/bjr.20190948. Epub 2020 Feb 26. Br J Radiol. 2020. PMID: 32101448 Free PMC article. Review.
-
Can Artificial Intelligence Beat Humans in Detecting Breast Malignancy on Mammograms?Cureus. 2023 Sep 29;15(9):e46208. doi: 10.7759/cureus.46208. eCollection 2023 Sep. Cureus. 2023. PMID: 37908910 Free PMC article.
-
Impact of full field digital mammography diagnosis for female patients with breast cancer.Medicine (Baltimore). 2019 Apr;98(16):e15175. doi: 10.1097/MD.0000000000015175. Medicine (Baltimore). 2019. PMID: 31008938 Free PMC article.
-
Diagnostic Performance of Artificial Intelligence-Based Computer-Aided Diagnosis for Breast Microcalcification on Mammography.Diagnostics (Basel). 2021 Aug 4;11(8):1409. doi: 10.3390/diagnostics11081409. Diagnostics (Basel). 2021. PMID: 34441343 Free PMC article.
References
-
- Shtern F. Digital mammography and related technologies: a perspective from the National Cancer Institute. Radiology. 1992;183:629–630. - PubMed
-
- Baum F, Fischer U, Obenauer S, Grabbe E. Computer-aided detection in direct digital full-field mammography: initial results. Eur Radiol. 2002;12:3015–3017. - PubMed