. 2013 Aug;26(4):768-73.
doi: 10.1007/s10278-012-9564-5.

Detection of breast cancer with a computer-aided detection applied to full-field digital mammography

Affiliations

Detection of breast cancer with a computer-aided detection applied to full-field digital mammography

Ryusuke Murakami et al. J Digit Imaging. 2013 Aug.

Abstract

A study was conducted to evaluate the sensitivity of computer-aided detection (CAD) with full-field digital mammography in detection of breast cancer, based on mammographic appearance and histopathology. Retrospectively, CAD sensitivity was assessed in total group of 152 cases for subgroups based on breast density, mammographic presentation, lesion size, and results of histopathological examination. The overall sensitivity of CAD was 91 % (139 of 152 cases). CAD detected 100 % (47/47) of cancers manifested as microcalcifications; 98 % (62/63) of those manifested as non-calcified masses; 100 % (15/15) of those manifested as mixed masses and microcalcifications; 75 % (12/16) of those manifested as architectural distortions, and 69 % (18/26) of those manifested as focal asymmetry. CAD sensitivity was 83 % (10/12) for cancers measuring 1-10 mm, 92 % (37/40) for those measuring 11-20 mm, and 92 % (92/100) for those measuring >20 mm. There was no significant difference in CAD detection efficiency between cancers in dense breasts (88 %; 69/78) and those in non-dense breasts (95 %; 70/74). CAD showed a high sensitivity of 91 % (139/152) for the mammographic appearance of cancer and 100 % sensitivity for identifying cancers manifested as microcalcifications. Sensitivity was not influenced by breast density or lesion size. CAD should be effective for helping radiologists detect breast cancer at an earlier stage.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Shtern F. Digital mammography and related technologies: a perspective from the National Cancer Institute. Radiology. 1992;183:629–630. - PubMed
    1. Pisano ED, Yaffe MJ. Digital mammography. Radiology. 2005;234:353–362. doi: 10.1148/radiol.2342030897. - DOI - PubMed
    1. Yang SK, Moon WK, Cho N, Park JS, Cha JH, Kim SM, Kim SJ, Im JG. Screening mammography-detected cancers: sensitivity of a computer-aided detection system applied to full-field digital mammograms. Radiology. 2007;244:104–111. doi: 10.1148/radiol.2441060756. - DOI - PubMed
    1. The JS, Schilling KJ, Hoffmeister JW, Friedmann E, McGinnis R, Holcomb RG. Detection of breast cancer with full-field digital mammography and computer-aided detection. AJR Am J Roentgenol. 2009;192:337–340. doi: 10.2214/AJR.07.3884. - DOI - PubMed
    1. Baum F, Fischer U, Obenauer S, Grabbe E. Computer-aided detection in direct digital full-field mammography: initial results. Eur Radiol. 2002;12:3015–3017. - PubMed