Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo
- PMID: 23319720
- DOI: 10.1258/ar.2012.120475
Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo
Abstract
Background: Isotropic three-dimensional (3D) magnetic resonance imaging (MRI) has been applied to various joints. However, comparison for image quality between isotropic 3D MRI and two-dimensional (2D) turbo spin echo (TSE) sequence of the wrist at a 3T MR system has not been investigated.
Purpose: To compare the image quality of isotropic 3D MRI including TSE intermediate-weighted (VISTA) sequence and fast field echo (FFE) sequence with 2D TSE intermediate-weighted sequence of the wrist joint at 3.0 T.
Material and methods: MRI was performed in 10 wrists of 10 healthy volunteers with isotropic 3D sequences (VISTA and FFE) and 2D TSE intermediate-weighted sequences at 3.0 T. The signal-to-noise ratio (SNR) was obtained by imaging phantom and noise-only image. Contrast ratios (CRs) were calculated between fluid and cartilage, triangular fibrocartilage complex (TFCC), and the scapholunate ligament. Two radiologists independently assessed the visibility of TFCC, carpal ligaments, cartilage, tendons and nerves with a four-point grading scale. Statistical analysis to compare CRs (one way ANOVA with a Tukey test) and grades of visibility (Kruskal-Wallis test) between three sequences and those for inter-observer agreement (kappa analysis) were performed.
Results: The SNR of 2D TSE (46.26) was higher than those of VISTA (23.34) and 3D FFE (19.41). CRs were superior in 2D TSE than VISTA (P = 0.02) for fluid-cartilage and in 2D TSE than 3D FFE (P < 0.01) for fluid-TFCC. The visibility was best in 2D TSE (P < 0.01) for TFCC and in VISTA (P = 0.01) for scapholunate ligament. The visibility was better in 2D TSE and 3D FFE (P = 0.04) for cartilage and in VISTA than 3D FFE (P < 0.01) for TFCC. The inter-observer agreement for the visibility of anatomic structures was moderate or substantial.
Conclusion: Image quality of 2D TSE was superior to isotropic 3D MR imaging for cartilage, and TFCC. 3D FFE has better visibility for cartilage than VISTA and VISTA has superior visibility for TFCC to 3D FFE and the visibility for scapholunate ligament was best on VISTA.
Similar articles
-
3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence.Acta Radiol. 2011 Dec 1;52(10):1119-24. doi: 10.1258/ar.2011.110328. Acta Radiol. 2011. PMID: 22144425
-
Three-dimensional isotropic T2-weighted cervical MRI at 3T: comparison with two-dimensional T2-weighted sequences.Clin Radiol. 2012 Feb;67(2):106-13. doi: 10.1016/j.crad.2011.06.011. Epub 2011 Dec 3. Clin Radiol. 2012. PMID: 22142499
-
Qualitative and quantitative assessment of isotropic ankle magnetic resonance imaging: three-dimensional isotropic intermediate-weighted turbo spin echo versus three-dimensional isotropic fast field echo sequences.Korean J Radiol. 2012 Jul-Aug;13(4):443-9. doi: 10.3348/kjr.2012.13.4.443. Epub 2012 Jun 18. Korean J Radiol. 2012. PMID: 22778566 Free PMC article.
-
3D isotropic MRI of ankle: review of literature with comparison to 2D MRI.Skeletal Radiol. 2024 May;53(5):825-846. doi: 10.1007/s00256-023-04513-2. Epub 2023 Nov 18. Skeletal Radiol. 2024. PMID: 37978990 Review.
-
Understanding 3D TSE Sequences: Advantages, Disadvantages, and Application in MSK Imaging.Semin Musculoskelet Radiol. 2015 Sep;19(4):321-7. doi: 10.1055/s-0035-1563732. Epub 2015 Nov 19. Semin Musculoskelet Radiol. 2015. PMID: 26583360 Review.
Cited by
-
Using a Dedicated Extremity MRI Scanner for Depicting Anatomic Structures of Common Wrist Pathologies: A Pilot Comparison with a 3-Tesla MRI Scanner.J Wrist Surg. 2022 May 30;12(2):147-154. doi: 10.1055/s-0042-1744366. eCollection 2023 Apr. J Wrist Surg. 2022. PMID: 36926212 Free PMC article.
-
High-resolution measurements of the multilayer ultra-structure of articular cartilage and their translational potential.Arthritis Res Ther. 2014 Mar 12;16(2):205. doi: 10.1186/ar4506. Arthritis Res Ther. 2014. PMID: 24946278 Free PMC article. Review.
-
Advanced imaging of the scapholunate ligamentous complex.Skeletal Radiol. 2015 Dec;44(12):1709-25. doi: 10.1007/s00256-015-2182-9. Epub 2015 Jul 30. Skeletal Radiol. 2015. PMID: 26219592 Review.
-
Visualization of wrist anatomy-a comparison between 7T and 3T MRI.Eur Radiol. 2022 Feb;32(2):1362-1370. doi: 10.1007/s00330-021-08165-5. Epub 2021 Aug 11. Eur Radiol. 2022. PMID: 34378077 Free PMC article.
-
Using an Office-Based, Dedicated Extremity MRI Scanner for Depicting Important Structures in Common Wrist Pathologies: A Pilot Comparison with a Conventional MRI Scanner.J Wrist Surg. 2021 Feb;10(1):84-92. doi: 10.1055/s-0040-1715799. Epub 2020 Oct 14. J Wrist Surg. 2021. PMID: 33552700 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials