. 2014 Feb;81(2):397-403.
doi: 10.1016/j.wneu.2013.01.039. Epub 2013 Jan 12.

Intraoperative ultrasound guidance for the placement of permanent ventricular cerebrospinal fluid shunt catheters: a single-center historical cohort study

Affiliations

Intraoperative ultrasound guidance for the placement of permanent ventricular cerebrospinal fluid shunt catheters: a single-center historical cohort study

R Webster Crowley et al. World Neurosurg. 2014 Feb.

Abstract

Objective: Despite the frequency with which ventriculoperitoneal shunts are placed, ventricular catheter revision rates remains as high as 30%-40% at 1 year. Many neurosurgeons place ventricular catheters "blindly" depending on anatomical landmarks and personal experience. To determine whether intraoperative ultrasonography is beneficial for ventricular catheter placement, we performed a historical cohort study comparing shunts placed with intraoperative ultrasound (US) guidance to those placed blindly.

Methods: We reviewed all shunts placed by the Department of Neurosurgery at the University of Virginia from January 2005 to January 2007. During that time 211 patients underwent 242 shunts, with US use determined by surgeon's preference. Ninety-two shunts were placed by the use of US guidance, and 150 were placed without US. Adults received 176 shunts, 56 with US. Children received 66 shunts, 36 with US. Mean follow-up was 21.6 months. The primary end points examined were shunt revision, ventricular catheter revision (VCR), and acute VCR (revision within 1 week for an improperly-placed catheter).

Results: The use of US was associated with a statistically significant decrease in shunt revisions (odds ratio 0.492; 95% confidence interval 0.253-0.958). Of the shunts placed with US guidance, 21.7% required revision, compared with 29.3% without US. VCRs and acute VCRs occurred in 9.8% and 2.2%, respectively, for US shunts, compared with 14% and 5.3% without US. Pediatric revision rates were 30.6% with US versus 53.3% without, whereas adult rates were 16.1% and 23.3%, respectively. The benefit of US was more profound for occipital shunts.

Conclusions: The use of US for the placement of permanent cerebrospinal fluid shunt catheters is associated with a decreased risk of shunt revision.

Keywords: Cerebrospinal fluid shunts; Hydrocephalus; Image-guided surgery.

PubMed Disclaimer

MeSH terms