Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Apr;28(4):819-22.
doi: 10.1128/jcm.28.4.819-822.1990.

Evaluation of the Recombigen HIV-1 Latex Agglutination Test

Affiliations

Evaluation of the Recombigen HIV-1 Latex Agglutination Test

C A Starkey et al. J Clin Microbiol. 1990 Apr.

Abstract

The Recombigen HIV-1 Latex Agglutination (LA) Test was recently licensed by the U.S. Food and Drug Administration for use as a rapid screening assay for human immunodeficiency virus type 1 (HIV-1) antibodies. However, its performance in various settings and in different populations has not been firmly established. Consequently, we evaluated the test in the Cleveland Clinic Retrovirus Laboratory, a regional reference laboratory for HIV diagnostic testing and a testing laboratory for the Ohio Department of Health Anonymous HIV Testing and Counseling Program. Serum samples from 93 individuals presumed to be at high risk for HIV infection were evaluated. The sera were initially tested for HIV antibodies by enzyme-linked immunosorbent assay (ELISA). All repeatedly reactive sera were subjected to confirmatory Western blot (WB; immunoblot) testing. Of 97 serum specimens tested (5 were from one seroconverter), 44 were repeatedly reactive by ELISA and 53 were nonreactive. Of the reactive serum specimens, 31 were confirmed positive and 12 were indeterminate by WB. All of the sera were coded and then retested by the LA test. Of 53 serum specimens nonreactive by ELISA, 51 were also nonreactive in the LA test. Of the 44 serum specimens reactive by ELISA, 16 were nonreactive by LA; however, 3 of the latter were WB positive. No serum specimen with an ELISA ratio (specimen optical density/cutoff optical density) of less than 2.1 scored reactive in the LA test. The LA test was positive for only two of five consecutive serum specimens from a seroconverter despite the fact that all but the earliest of these were ELISA reactive and WB positive. Although the LA test appears to be an adequate first-line screening test when appropriately used according to the directions of the manufacturer, our data suggest that occasional sera with low levels of reactivity by ELISA may not be readily detected as reactive by the LA test.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Science. 1986 Nov 21;234(4779):955-63 - PubMed
    1. J Clin Microbiol. 1987 Jul;25(7):1207-12 - PubMed
    1. J Clin Microbiol. 1987 Sep;25(9):1772-3 - PubMed
    1. J Clin Microbiol. 1988 Mar;26(3):552-6 - PubMed
    1. Infect Control Hosp Epidemiol. 1989 Aug;10(8):354-67 - PubMed

LinkOut - more resources