Case Reports
. 2013 Mar;251(3):667-75.
doi: 10.1007/s00417-012-2254-7. Epub 2013 Jan 17.

Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation

Affiliations
Case Reports

Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation

Cesare Forlini et al. Graefes Arch Clin Exp Ophthalmol. 2013 Mar.

Abstract

Background: Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia.

Methods: Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel.

Results: Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque.

Conclusion: Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. J Cataract Refract Surg. 2000 Mar;26(3):375-81 - PubMed
    1. J Cataract Refract Surg. 2008 Oct;34(10):1674-80 - PubMed
    1. J Cataract Refract Surg. 1999 Nov;25(11):1540-7 - PubMed
    1. J Cataract Refract Surg. 2012 Feb;38(2):362-7 - PubMed
    1. Clin Exp Ophthalmol. 2002 Aug;30(4):266-9 - PubMed

Publication types