Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Apr;37(4):409-16.
doi: 10.1111/j.1525-1594.2012.01570.x. Epub 2013 Jan 18.

Removal of protein-bound, hydrophobic uremic toxins by a combined fractionated plasma separation and adsorption technique

Affiliations

Removal of protein-bound, hydrophobic uremic toxins by a combined fractionated plasma separation and adsorption technique

Falko Brettschneider et al. Artif Organs. 2013 Apr.

Abstract

Protein-bound uremic toxins, such as phenylacetic acid, indoxyl sulfate, and p-cresyl sulfate, contribute substantially to the progression of chronic kidney disease (CKD) and cardiovascular disease (CVD). However, based on their protein binding, these hydrophobic uremic toxins are poorly cleared during conventional dialysis and thus accumulate in CKD-5D patients. Therefore, we investigated whether hydrophobic and cationic adsorbers are more effective for removal of protein-bound, hydrophobic uremic toxins than conventional high-flux hemodialyzer. Five CKD-5D patients were treated using the fractionated plasma separation, adsorption, and dialysis (FPAD) system for 5 h. A control group of five CKD patients was treated with conventional high-flux hemodialysis. Plasma concentrations of phenylacetic acid, indoxyl sulfate, and p-cresyl sulfate were measured. Removal rates of FPAD treatment in comparison to conventional high-flux hemodialysis were increased by 130% for phenylacetic acid, 187% for indoxyl sulfate, and 127% for p-cresol. FPAD treatment was tolerated well in terms of clinically relevant biochemical parameters. However, patients suffered from mild nausea 2 h after the start of the treatment, which persisted until the end of treatment. Due to the high impact of protein-bound, hydrophobic uremic toxins on progression of CKD and CVD in CKD-5D patients, the use of an adsorber in combination with dialysis membranes may be a new therapeutic option to increase the removal rate of these uremic toxins. However, larger, long-term prospective clinical trials are needed to demonstrate the impact on clinical outcome.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

MeSH terms