Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Jul;30(6):682-92.
doi: 10.1111/echo.12115. Epub 2013 Jan 24.

Three-dimensional echocardiography in the evaluation of global and regional function in patients with recent myocardial infarction: a comparison with magnetic resonance imaging

Affiliations
Comparative Study

Three-dimensional echocardiography in the evaluation of global and regional function in patients with recent myocardial infarction: a comparison with magnetic resonance imaging

Anders Thorstensen et al. Echocardiography. 2013 Jul.

Abstract

We aimed to compare three-dimensional (3D) and two-dimensional (2D) echocardiography in the evaluation of patients with recent myocardial infarction (MI), using late-enhancement magnetic resonance imaging (LE-MRI) as a reference method. Echocardiography and LE-MRI were performed approximately 1 month after first-time MI in 58 patients. Echocardiography was also performed on 35 healthy controls. Left ventricular (LV) ejection fraction by 3D echocardiography (3D-LVEF), 3D wall-motion score (WMS), 2D-WMS, 3D speckle tracking-based longitudinal, circumferential, transmural and area strain, and 2D speckle tracking-based longitudinal strain (LS) were measured. The global correlations to infarct size by LE-MRI were significantly higher (P < 0.03) for 3D-WMS and 2D-WMS compared with 3D-LVEF and the 4 different measurements of 3D strain, and 2D global longitudinal strain (GLS) was more closely correlated to LE-MRI than 3D GLS (P < 0.03). The segmental correlations to infarct size by LE-MRI were also significantly higher (P < 0.04) for 3D-WMS, 2D-WMS, and 2D LS compared with the other indices. Three-dimensional WMS showed a sensitivity of 76% and a specificity of 72% for identification of LV infarct size >12%, and a sensitivity of 73% and a specificity of 95% for identification of segments with transmural infarct extension. Three-dimensional WMS and 2D gray-scale echocardiography showed the strongest correlations to LE-MRI. The tested 3D strain method suffers from low temporal and spatial resolution in 3D acquisitions and added diagnostic value could not be proven.

Keywords: coronary artery disease; myocardial contrast enhancement; myocardial infarction; strain; three-dimensional echocardiography; wall-motion score.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources