Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jul-Aug;28(4):496-502.
doi: 10.1002/bio.2482. Epub 2013 Jan 27.

Highly sensitive chemiluminescence immunoassay on chitosan membrane modified paper platform using TiO2 nanoparticles/multiwalled carbon nanotubes as label

Affiliations

Highly sensitive chemiluminescence immunoassay on chitosan membrane modified paper platform using TiO2 nanoparticles/multiwalled carbon nanotubes as label

Weiping Li et al. Luminescence. 2013 Jul-Aug.

Abstract

A highly sensitive chemiluminescence (CL) immunoassay was incorporated into a low-cost microfluidic paper-based analytical device (μ-PAD) to fabricate a facile paper-based CL immunodevice (denoted as μ-PCLI). This μ-PCLI was constructed by covalently immobilizing capture antibody on a chitosan membrane modified μ-PADs, which was developed by simple wax printing methodology. TiO2 nanoparticles coated multiwalled carbon nanotubes (TiO2/MWCNTs) were synthesized as an amplification catalyst tag to label signal antibody (Ab2). After sandwich-type immunoreactions, the TiO2/MWCNTs were captured on the surface of μ-PADs to catalyze the luminol-p-iodophenol-H2O2 CL system, which produced an enhanced CL emission. Using prostate-specific antigen as a model analyte, the approach provided a good linear response range from 0.001 to 20 ng/mL with a low detection limit of 0.8 pg/mL under optimal conditions. This μ-PCLI showed good reproducibility, selectivity and stability. The assay results of prostate-specific antigen in clinical serum samples were in good agreement with that obtained by commercially used electrochemiluminescence methods at the Cancer Research Center of Shandong Tumor Hospital (Jinan, Shandong Province, China). This μ-PCLI could be very useful to realize highly sensitive, qualitative point-of-care testing in developing or developed countries.

Keywords: TiO2 nanoparticles coated multi-walled carbon nanotubes; chemiluminescence immunoassay; chitosan membrane; lab on chip; point-of-care.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources