Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Oct;41(7):e111-6.
doi: 10.1016/j.jcms.2012.11.036. Epub 2013 Jan 26.

Lower eyelid suspension using polypropylene suture for the correction of punctal ectropion

Affiliations

Lower eyelid suspension using polypropylene suture for the correction of punctal ectropion

Ruchi Goel et al. J Craniomaxillofac Surg. 2013 Oct.

Abstract

Objective: To evaluate the efficacy and complications of lower eyelid suspension with the modified Safdarjung hospital technique using 5:0 polypropylene suture for punctal ectropion.

Study design: Prospective case series.

Method: Thirty one eyelids in 19 patients with mild and moderate ectropion and all types of laxity including involutional and paralytic were included. All patients underwent lower eyelid suspension with the modified Safdarjung hospital technique. A 5:0 polypropylene suture was passed in the pre-tarsal plane between the attachments of the lateral and medial canthal tendons near their insertion at the orbital rim. Successful outcome was judged by the anatomical restoration of the apposition of the punctum to the globe in the upward gaze and the physiological relief of epiphora. The recurrence of lid laxity, overall lid/globe apposition and complications were also noted.

Results: At 1 year follow up anatomical success was achieved in 28 (90%) patients and functional success noted in 27 (87%) patients. Recurrence of lid laxity was noted in 2 patients. There was a suture exposure in one case and a suture granuloma in another case. The results did not correlate to the degree of ectropion and type of laxity.

Conclusion: Lower eyelid suspension using 5:0 polypropylene suture is a useful procedure for the treatment of involutional and paralytic punctal ectropion. It is simple and effective with minimal complications. However, the effect on scleral show and the concern related to suture material biodegradation over years needs to be further evaluated.

Keywords: Ectropion; Epiphora; Lid laxity; Lower eyelid suspension; Polypropylene suture.

PubMed Disclaimer

MeSH terms

LinkOut - more resources