Placental thickness & its correlation to gestational age & foetal growth parameters- a cross sectional ultrasonographic study
- PMID: 23373039
- PMCID: PMC3552215
- DOI: 10.7860/JCDR/2012/4867.2652
Placental thickness & its correlation to gestational age & foetal growth parameters- a cross sectional ultrasonographic study
Abstract
Background: The Gestational Age (GA) is frequently over or under estimated, as the conventional gestational estimation is based on the Last Menstrual Period (LMP) and on ultrasonography (USG). Many people are unaware of their LMP and irregular menstruations and USG is bound to have a bias, thereby posing difficulties in the GA estimation.
Aim: This study was aimed at estimating the (Placental Thickness) PT and at investigating the relationship between PT and the foetal growth parameters in normal singleton pregnancies.
Materials and methods: Two hundred eleven pregnant women were recruited in a cross sectional prospective study. The pregnancies were between 11 to 40 weeks and they were not complicated by either maternal or foetal diseases. The Biparietal Diameter (BPD), the Abdominal Circumference (AC), the Head Circumference (HC), the Femur Length (FL) and the PT were measured by USG by using a 3.5 MHz transducer.
Results: The maximum mean PT in the 1st, 2nd, 3rd and the combined trimesters were 16.5 mm, 23.78 mm, 35.81 mm and 28.49 mm respectively. The correlation between PT and the other foetal parameters was investigated by Pearson's correlation analysis. The values were expressed as mean + standard deviation. The statistical tests were two-tailed, with a p value of < 0.01, which indicated the statistical significance. There was a strong positive correlation between PT and GA, with the correlation coefficient values for the 1st, 2nd and 3rd trimesters being r = 0.609, r = 0.812 and r = 0.814 respectively. There was a significant positive correlation between PT and BPD, AC, FL, ABC, HC and FW also. The mathematical relationships between PT and GA, BPD, AC, FL, ABC, HC, FW were derived by regression analysis. The regression equation which was derived was (x - 22.92) = (0.3604) (w-27.86446) + (1.0256)(y-1.1678) + (0.0015)(z-216.2841) + (0.1047) (t-43.1555) + (0.027) (u.192.79000) + (0.0042) (v-60.3725), where x = GA in weeks, w = PT in mm, y = FW in kg, z = HC in mm, t = FL in mm, u = AC in mm and v = BPD in mm.
Conclusion: We conclude that PT can be used as a predictor of the GA. The subnormal PT for the corresponding GA should be evaluated for any disease condition. So, the measurement of PT should therefore be carried out routinely during the obstetric USGs.
Keywords: Gestational age; Last menstrual period; Placental thickness; Ultrasonography.
Figures
Similar articles
-
Ultrasonographic measurement of the transcerebellar diameter for gestational age estimation in the third trimester.J Ultrasound. 2022 Jun;25(2):281-287. doi: 10.1007/s40477-021-00564-0. Epub 2021 Mar 9. J Ultrasound. 2022. PMID: 33687690 Free PMC article.
-
Ultrasound Measurement of Placental Thickness: A Reliable Estimation of Gestational Age in Normal Singleton Pregnancies in Nigerian Women.J West Afr Coll Surg. 2022 Jan-Mar;12(1):17-22. doi: 10.4103/jwas.jwas_72_22. Epub 2022 Aug 23. J West Afr Coll Surg. 2022. PMID: 36203931 Free PMC article.
-
Significance of Foetal Transcerebellar Diameter in Foetal Biometry: A Pilot Study.J Clin Diagn Res. 2017 Jun;11(6):TC01-TC04. doi: 10.7860/JCDR/2017/23583.9968. Epub 2017 Jun 1. J Clin Diagn Res. 2017. PMID: 28764260 Free PMC article.
-
Determination of the Accuracy of Transcerebellar Diameter in Estimating Gestational Age in the Second and Third Trimesters of Pregnancy.Cureus. 2024 Jun 27;16(6):e63292. doi: 10.7759/cureus.63292. eCollection 2024 Jun. Cureus. 2024. PMID: 39070496 Free PMC article.
-
Mean Fetal Kidney Length at the Third Trimester: An Emerging Ultrasound Parameter for Gestational Age Assessment.Cureus. 2025 Jan 21;17(1):e77796. doi: 10.7759/cureus.77796. eCollection 2025 Jan. Cureus. 2025. PMID: 39981493 Free PMC article.
Cited by
-
Correlation of ultrasound placental diameter & thickness with gestational age.Pak J Med Sci. 2020 Jul-Aug;36(5):1058-1062. doi: 10.12669/pjms.36.5.1938. Pak J Med Sci. 2020. PMID: 32704289 Free PMC article.
-
Unveiling the human fetal-maternal interface during the first trimester: biophysical knowledge and gaps.Front Cell Dev Biol. 2024 Jul 31;12:1411582. doi: 10.3389/fcell.2024.1411582. eCollection 2024. Front Cell Dev Biol. 2024. PMID: 39144254 Free PMC article. Review.
-
Relationship between sonographic umbilical cord size and gestational age among pregnant women in Enugu, Nigeria.Afr Health Sci. 2014 Jun;14(2):334-8. doi: 10.4314/ahs.v14i2.7. Afr Health Sci. 2014. PMID: 25320581 Free PMC article.
-
Using mechanistic physiologically-based pharmacokinetic models to assess prenatal drug exposure: Thalidomide versus efavirenz as case studies.Eur J Pharm Sci. 2019 Dec 1;140:105068. doi: 10.1016/j.ejps.2019.105068. Epub 2019 Sep 10. Eur J Pharm Sci. 2019. PMID: 31518681 Free PMC article.
-
A flexible generative algorithm for growing in silico placentas.PLoS Comput Biol. 2024 Oct 7;20(10):e1012470. doi: 10.1371/journal.pcbi.1012470. eCollection 2024 Oct. PLoS Comput Biol. 2024. PMID: 39374295 Free PMC article.
References
-
- Callen PW, editor. Ultrasonography in Obstetrics and Gynaecology. 5th ed. Philadelphia: Elsevier, a division of Reed Elsevier India Limited; 2002. pp. 225–65. Chapter 7 – USG evaluation of foetal biometry & abnormal growth.
-
- Malhotra N, Kumar P. Ultrasound in Obstetrics andGynaecology. 3rd ed. Mumbai: Jaypee Brothers Medical Publishers Private Ltd; 1999. Chapter 11, Measurement of foetal parameters; Chapter 27, Ultrasound and admission test in labour. Chapter 55, Pitfalls in USG;pp92-98,198-200,386-88.
-
- Wolfson RN, Zador IE, Havorsen P, Andrews B, Sokol RJ. Biparietal diameter in premature rupture of membranes: Errors in estimating gestational age. J Clin Ultrasound. 1983;11:371–74. - PubMed
-
- Nyberg DA, Finberg HJ. The placenta, placental membranes and umbilical cord. Journal on diagnostic ultrasound of foetal anomalies. 1990;21(4):623–75.
-
- Kunlmann RS, Warsof S. Ultrasound of the placenta. Clin Afr. Jou Obstet. Gynecol. 1996;39:34. - PubMed
LinkOut - more resources
Full Text Sources
Medical