Graphics processing unit accelerated optical coherence tomography processing at megahertz axial scan rate and high resolution video rate volumetric rendering
- PMID: 23377003
- DOI: 10.1117/1.JBO.18.2.026002
Graphics processing unit accelerated optical coherence tomography processing at megahertz axial scan rate and high resolution video rate volumetric rendering
Abstract
In this report, we describe how to highly optimize a computer unified device architecture based platform to perform real-time processing of optical coherence tomography interferometric data and three-dimensional (3-D) volumetric rendering using a commercially available, cost-effective, graphics processing unit (GPU). The maximum complete attainable axial scan processing rate, including memory transfer and displaying B-scan frame, was 2.24 MHz for 16 bits pixel depth and 2048 fast Fourier transform size; the maximum 3-D volumetric rendering rate, including B-scan, en face view display, and 3-D rendering, was ~23 volumes/second (volume size: 1024×256×200). To the best of our knowledge, this is the fastest processing rate reported to date with a single-chip GPU and the first implementation of real-time video-rate volumetric optical coherence tomography (OCT) processing and rendering that is capable of matching the acquisition rates of ultrahigh-speed OCT.
Similar articles
-
Real-time 4D signal processing and visualization using graphics processing unit on a regular nonlinear-k Fourier-domain OCT system.Opt Express. 2010 May 24;18(11):11772-84. doi: 10.1364/OE.18.011772. Opt Express. 2010. PMID: 20589038 Free PMC article.
-
Processing and rendering of Fourier domain optical coherence tomography images at a line rate over 524 kHz using a graphics processing unit.J Biomed Opt. 2011 Feb;16(2):020505. doi: 10.1117/1.3548153. J Biomed Opt. 2011. PMID: 21361661
-
Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning.Eur Rev Med Pharmacol Sci. 2022 Oct;26(20):7349-7358. doi: 10.26355/eurrev_202210_30004. Eur Rev Med Pharmacol Sci. 2022. PMID: 36314305
-
State-of-the-art retinal optical coherence tomography.Prog Retin Eye Res. 2008 Jan;27(1):45-88. doi: 10.1016/j.preteyeres.2007.07.005. Epub 2007 Aug 11. Prog Retin Eye Res. 2008. PMID: 18036865 Review.
-
Combining SLO and OCT technology.Bull Soc Belge Ophtalmol. 2006;(302):133-51. Bull Soc Belge Ophtalmol. 2006. PMID: 17265795 Review.
Cited by
-
Enhanced volumetric visualization for real time 4D intraoperative ophthalmic swept-source OCT.Biomed Opt Express. 2016 Apr 12;7(5):1815-29. doi: 10.1364/BOE.7.001815. eCollection 2016 May 1. Biomed Opt Express. 2016. PMID: 27231623 Free PMC article.
-
Adaptive optics optical coherence tomography for in vivo mouse retinal imaging.J Biomed Opt. 2013 May;18(5):56007. doi: 10.1117/1.JBO.18.5.056007. J Biomed Opt. 2013. PMID: 23644903 Free PMC article.
-
Bimodal in vivo imaging provides early assessment of stem-cell-based photoreceptor engraftment.Eye (Lond). 2015 May;29(5):681-90. doi: 10.1038/eye.2015.24. Epub 2015 Mar 13. Eye (Lond). 2015. PMID: 25771816 Free PMC article.
-
Artifacts and artifact removal in optical coherence tomographic angiography.Quant Imaging Med Surg. 2021 Mar;11(3):1120-1133. doi: 10.21037/qims-20-730. Quant Imaging Med Surg. 2021. PMID: 33654681 Free PMC article. Review.
-
Segmental biomechanics of the normal and glaucomatous human aqueous outflow pathway.Acta Biomater. 2024 Jan 1;173:148-166. doi: 10.1016/j.actbio.2023.11.003. Epub 2023 Nov 7. Acta Biomater. 2024. PMID: 37944773 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials