Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry
- PMID: 23377008
- DOI: 10.1117/1.JBO.18.2.027001
Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry
Abstract
A Cerenkov fiber-optic dosimeter (CFOD) is fabricated using plastic optical fibers to measure Cerenkov radiation induced by a therapeutic photon beam. We measured the Cerenkov radiation generated in optical fibers in various irradiation conditions to evaluate the usability of Cerenkov radiation for a photon beam therapy dosimetry. As a results, the spectral peak of Cerenkov radiation was measured at a wavelength of 515 nm, and the intensity of Cerenkov radiation increased linearly with increasing irradiated length of the optical fiber. Also, the intensity peak of Cerenkov radiation was measured in the irradiation angle range of 30 to 40 deg. In the results of Monte Carlo N-particle transport code simulations, the relationship between fluxes of electrons over Cerenkov threshold energy and energy deposition of a 6 MV photon beam had a nearly linear trend. Finally, percentage depth doses for the 6 MV photon beam could be obtained using the CFOD and the results were compared with those of an ionization chamber. Here, the mean dose difference was about 0.6%. It is anticipated that the novel and simple CFOD can be effectively used for measuring depth doses in radiotherapy dosimetry.
Similar articles
-
The visible signal responsible for proton therapy dosimetry using bare optical fibers is not Čerenkov radiation.Med Phys. 2016 Nov;43(11):5973. doi: 10.1118/1.4964453. Med Phys. 2016. PMID: 27806617
-
Simultaneous measurements of pure scintillation and Cerenkov signals in an integrated fiber-optic dosimeter for electron beam therapy dosimetry.Opt Express. 2013 Nov 18;21(23):27770-9. doi: 10.1364/OE.21.027770. Opt Express. 2013. PMID: 24514292
-
Feasibility study on development of Cerenkov fiber-optic dosimeter for radiotherapy application.Annu Int Conf IEEE Eng Med Biol Soc. 2013;2013:485-7. doi: 10.1109/EMBC.2013.6609542. Annu Int Conf IEEE Eng Med Biol Soc. 2013. PMID: 24109729
-
Nanoparticles for Cerenkov and Radioluminescent Light Enhancement for Imaging and Radiotherapy.Nanomaterials (Basel). 2020 Sep 7;10(9):1771. doi: 10.3390/nano10091771. Nanomaterials (Basel). 2020. PMID: 32906838 Free PMC article. Review.
-
Recent Advances in Optical Fiber Enabled Radiation Sensors.Sensors (Basel). 2022 Feb 1;22(3):1126. doi: 10.3390/s22031126. Sensors (Basel). 2022. PMID: 35161870 Free PMC article. Review.
Cited by
-
Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.Sensors (Basel). 2014 Apr 1;14(4):6305-16. doi: 10.3390/s140406305. Sensors (Basel). 2014. PMID: 24694678 Free PMC article.
-
Video-rate optical dosimetry and dynamic visualization of IMRT and VMAT treatment plans in water using Cherenkov radiation.Med Phys. 2014 Jun;41(6):062102. doi: 10.1118/1.4875704. Med Phys. 2014. PMID: 24877829 Free PMC article.
-
Commissioning an Exradin W2 plastic scintillation detector for clinical use in small radiation fields.J Appl Clin Med Phys. 2022 Aug;23(8):e13728. doi: 10.1002/acm2.13728. Epub 2022 Jul 21. J Appl Clin Med Phys. 2022. PMID: 35861648 Free PMC article.
-
Second window near-infrared dosimeter (NIR2D) system for radiation dosimetry.Phys Med Biol. 2020 Aug 31;65(17):175013. doi: 10.1088/1361-6560/ab9b56. Phys Med Biol. 2020. PMID: 32869751 Free PMC article.
-
Measurement of Cerenkov radiation induced by the gamma-rays of Co-60 therapy units using wavelength shifting fiber.Sensors (Basel). 2014 Apr 21;14(4):7013-25. doi: 10.3390/s140407013. Sensors (Basel). 2014. PMID: 24755521 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials