Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Feb;69(Pt 2):150-67.
doi: 10.1107/S0907444912044423. Epub 2013 Jan 19.

Techniques, tools and best practices for ligand electron-density analysis and results from their application to deposited crystal structures

Affiliations
Comparative Study

Techniques, tools and best practices for ligand electron-density analysis and results from their application to deposited crystal structures

Edwin Pozharski et al. Acta Crystallogr D Biol Crystallogr. 2013 Feb.

Abstract

As a result of substantial instrumental automation and the continuing improvement of software, crystallographic studies of biomolecules are conducted by non-experts in increasing numbers. While improved validation almost ensures that major mistakes in the protein part of structure models are exceedingly rare, in ligand-protein complex structures, which in general are most interesting to the scientist, ambiguous ligand electron density is often difficult to interpret and the modelled ligands are generally more difficult to properly validate. Here, (i) the primary technical reasons and potential human factors leading to problems in ligand structure models are presented; (ii) the most common categories of building errors or overinterpretation are classified; (iii) a few instructive and specific examples are discussed in detail, including an electron-density-based analysis of ligand structures that do not contain any ligands; (iv) means of avoiding such mistakes are suggested and the implications for database validity are discussed and (v) a user-friendly software tool that allows non-expert users to conveniently inspect ligand density is provided.

Keywords: evidence-based reasoning; omit difference density; protein–ligand structures; validation.

PubMed Disclaimer

Similar articles

Cited by

  • FEM: feature-enhanced map.
    Afonine PV, Moriarty NW, Mustyakimov M, Sobolev OV, Terwilliger TC, Turk D, Urzhumtsev A, Adams PD. Afonine PV, et al. Acta Crystallogr D Biol Crystallogr. 2015 Mar;71(Pt 3):646-66. doi: 10.1107/S1399004714028132. Epub 2015 Feb 26. Acta Crystallogr D Biol Crystallogr. 2015. PMID: 25760612 Free PMC article.
  • Ligand fitting with CCP4.
    Nicholls RA. Nicholls RA. Acta Crystallogr D Struct Biol. 2017 Feb 1;73(Pt 2):158-170. doi: 10.1107/S2059798316020143. Epub 2017 Feb 1. Acta Crystallogr D Struct Biol. 2017. PMID: 28177312 Free PMC article.
  • Twilight reloaded: the peptide experience.
    Weichenberger CX, Pozharski E, Rupp B. Weichenberger CX, et al. Acta Crystallogr D Struct Biol. 2017 Mar 1;73(Pt 3):211-222. doi: 10.1107/S205979831601620X. Epub 2017 Feb 28. Acta Crystallogr D Struct Biol. 2017. PMID: 28291756 Free PMC article.
  • Crystallographic models of SARS-CoV-2 3CLpro: in-depth assessment of structure quality and validation.
    Jaskolski M, Dauter Z, Shabalin IG, Gilski M, Brzezinski D, Kowiel M, Rupp B, Wlodawer A. Jaskolski M, et al. IUCrJ. 2021 Feb 9;8(Pt 2):238-256. doi: 10.1107/S2052252521001159. eCollection 2021 Mar 1. IUCrJ. 2021. PMID: 33708401 Free PMC article.
  • Pan-HSP90 ligand binding reveals isoform-specific differences in plasticity and water networks.
    Stachowski TR, Nithianantham S, Vanarotti M, Lopez K, Fischer M. Stachowski TR, et al. Protein Sci. 2023 May;32(5):e4629. doi: 10.1002/pro.4629. Protein Sci. 2023. PMID: 36938943 Free PMC article.

Publication types