Incidence of and risk factors for superior facet violation in minimally invasive versus open pedicle screw placement during transforaminal lumbar interbody fusion: a comparative analysis
- PMID: 23394166
- DOI: 10.3171/2013.1.SPINE12882
Incidence of and risk factors for superior facet violation in minimally invasive versus open pedicle screw placement during transforaminal lumbar interbody fusion: a comparative analysis
Abstract
Object: A reported risk factor for adjacent-segment disease is injury to the superior facet joint from pedicle screw placement. Given that the facet joint is not typically visualized during percutaneous pedicle screw insertion, there is a concern for increased facet violation (FV) in minimally invasive fusion procedures. The purpose of this study was to analyze and compare the incidence of FV among patients undergoing minimally invasive transforaminal lumbar interbody fusion (MITLIF) and open transforaminal lumbar interbody fusion (TLIF). The impact of O-arm navigation compared with traditional fluoroscopy on FV in MITLIF is also assessed, as are risk factors for FV.
Methods: The authors identified a consecutive population of patients who underwent MITLIF with percutaneous pedicle screw placement, as well as a matched cohort of patients who underwent open TLIF. Postoperative CT imaging was assessed to determine intraarticular FV due to pedicle screw placement. Patients were stratified into minimally invasive and open TLIF groups. Within the MITLIF group, the authors performed a subanalysis of image guidance methods used in cases of FV. Two-tailed Student t-test, ANOVA, chi-square testing, and logistic regression were used for statistical analysis.
Results: A total of 282 patients were identified, with a total of 564 superior pedicle screw placements. The MITLIF group consisted of 142 patients with 284 screw insertions. The open TLIF group consisted of 140 patients with 280 screw insertions. Overall, 21 (7.4%) of 282 patients experienced FV. A total of 21 screws violated a facet joint for a screw-based FV rate of 3.7% (21 of 564 screws). There were no significant differences between the MITLIF and open TLIF groups in the percentage of patients with FV (6.3% vs 8.6%) and or the percentage of screws with FV (3.2% vs 4.3%) (p = 0.475 and p = 0.484, respectively). Further stratifying the MI group into O-arm navigation and fluoroscopic guidance subgroups, the patient-based rates of FV were 10.8% (4 of 37 patients) and 4.8% (5 of 105 patients), respectively, and the screw-based rates of FV were 5.4% (4 of 74 screws) and 2.4% (5 of 210 screws), respectively. There was no significant difference between the subgroups with respect to patient-based or screw-based FV rates (p = 0.375 and p = 0.442, respectively). The O-arm group had a significantly higher body mass index (BMI) (p = 0.021). BMI greater than 29.9 was independently associated with higher FV (OR 2.36, 95% CI 1.65-8.53, p = 0.039).
Conclusions: The findings suggest that minimally invasive pedicle screw placement is not associated with higher rates of FV. Overall violation rates were similar in MITLIF and open TLIF. Higher BMI, however, was a risk factor for increased FV. The use of O-arm fluoroscopy with computer-assisted guidance did not significantly decrease the rate of FV.
Similar articles
-
Risk Factors Related to Superior Facet Joint Violation During Lumbar Percutaneous Pedicle Screw Placement in Minimally Invasive Transforaminal Lumbar Interbody Fusion (MIS-TLIF).World Neurosurg. 2020 Jul;139:e716-e723. doi: 10.1016/j.wneu.2020.04.118. Epub 2020 Apr 28. World Neurosurg. 2020. PMID: 32360675
-
Incidence and Risk Factors for Facet Joint Violation in Open Versus Minimally Invasive Procedures During Pedicle Screw Placement in Patients with Trauma.World Neurosurg. 2018 Apr;112:e711-e718. doi: 10.1016/j.wneu.2018.01.138. Epub 2018 Jan 31. World Neurosurg. 2018. PMID: 29391300
-
Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation.Spine (Phila Pa 1976). 2013 Feb 15;38(4):E251-8. doi: 10.1097/BRS.0b013e31827ecbf1. Spine (Phila Pa 1976). 2013. PMID: 23197012
-
Comparison of robot-assisted versus fluoroscopy-guided transforaminal lumbar interbody fusion (TLIF) for lumbar degenerative diseases: a systematic review and meta-analysis of randomized controlled trails and cohort studies.Syst Rev. 2024 Jul 5;13(1):170. doi: 10.1186/s13643-024-02600-6. Syst Rev. 2024. PMID: 38970142 Free PMC article.
-
Open versus minimally invasive TLIF: literature review and meta-analysis.J Orthop Surg Res. 2019 Jul 22;14(1):229. doi: 10.1186/s13018-019-1266-y. J Orthop Surg Res. 2019. PMID: 31331364 Free PMC article. Review.
Cited by
-
The evolution of image-guided lumbosacral spine surgery.Ann Transl Med. 2015 Apr;3(5):69. doi: 10.3978/j.issn.2305-5839.2015.02.01. Ann Transl Med. 2015. PMID: 25992368 Free PMC article. Review.
-
Comparison of outcomes between cortical screws and traditional pedicle screws for lumbar interbody fusion: a systematic review and meta-analysis.J Orthop Surg Res. 2019 Aug 23;14(1):269. doi: 10.1186/s13018-019-1311-x. J Orthop Surg Res. 2019. PMID: 31443671 Free PMC article.
-
Multivariate analysis of pedicle screw invasion of the proximal facet joint after lumbar surgery.BMC Musculoskelet Disord. 2022 Jan 6;23(1):39. doi: 10.1186/s12891-021-04975-2. BMC Musculoskelet Disord. 2022. PMID: 34991578 Free PMC article.
-
Postoperative Outcome of Robot-Assisted Transforaminal Lumbar Interbody Fusion: A Pilot Study.Asian J Neurosurg. 2021 Dec 18;16(4):759-764. doi: 10.4103/ajns.AJNS_558_20. eCollection 2021 Oct-Dec. Asian J Neurosurg. 2021. PMID: 35071074 Free PMC article.
-
Facet angle and its importance on joint violation in percutaneous pedicle screw fixation in lumbar vertebrae: A retrospective study.Medicine (Baltimore). 2018 Jun;97(22):e10943. doi: 10.1097/MD.0000000000010943. Medicine (Baltimore). 2018. PMID: 29851835 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical