Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2013 Mar;116(3):636-43.
doi: 10.1213/ANE.0b013e31827e4e29. Epub 2013 Feb 11.

A randomized controlled comparison of epidural analgesia and combined spinal-epidural analgesia in a private practice setting: pain scores during first and second stages of labor and at delivery

Affiliations
Randomized Controlled Trial

A randomized controlled comparison of epidural analgesia and combined spinal-epidural analgesia in a private practice setting: pain scores during first and second stages of labor and at delivery

David Gambling et al. Anesth Analg. 2013 Mar.

Abstract

Background: There has been no prospective evaluation of combined spinal-epidural (CSE) analgesia in a private practice setting and few studies have focused on pain relief during the second stage of labor and at delivery. In this randomized controlled trial, we compared verbal pain scores during the first and second stages of labor and at delivery in women receiving CSE or traditional epidural analgesia at a busy private maternity hospital.

Methods: Healthy, term parturients received epidural or CSE analgesia for labor pain upon request. Epidural analgesia was initiated with 0.125% bupivacaine plus 2 μg/mL fentanyl, 15 mL; CSE analgesia was initiated with intrathecal plain bupivacaine 3.125 mg plus 5 μg fentanyl. Thereafter, patient-controlled epidural analgesia with 0.125% bupivacaine plus 2 μg/mL fentanyl was used for maintenance analgesia in both groups. The primary outcome was an assessment of "typical" pain, using a verbal rating pain score from 0 to 10, made at the end of the first stage of labor and shortly after delivery.

Results: Data from 398 epidural and 402 CSE subjects were analyzed. The typical verbal rating pain score during the first stage was lower in the CSE group (mean: 1.4 vs 1.9; P < 0.001; 99.5% confidence interval [CI] for difference: -0.92, -0.14). Pain scores during the second stage of labor (1.7 vs 1.9; P = 0.17; 99.5% CI for difference: -0.82, 0.28) and at delivery (2.0 vs 2.0; P = 0.77; 99.5% CI for difference: -0.73, 0.59) were the same between groups. Fewer patients received an epidural top-up dose in the CSE group (16.4% vs 25.6%; P = 0.002; 99.5% CI for difference: -17.0%, -1.0%). Epidural catheters were replaced in 1.2% CSE vs 2% in the epidural group (P = 0.39; 99.5% CI for difference: -3.3%, 1.8%).

Conclusions: Compared with traditional epidural labor analgesia, CSE analgesia provided better first-stage analgesia despite fewer epidural top-up injections by an anesthesiologist.

PubMed Disclaimer

Comment in

Publication types

Substances