[Normal database (NDB) of 123I-IMP brain perfusion SPECT examination is affected by statistical image analysis in the presence or absence of scatter correction and attenuation correction]
- PMID: 23402204
[Normal database (NDB) of 123I-IMP brain perfusion SPECT examination is affected by statistical image analysis in the presence or absence of scatter correction and attenuation correction]
Abstract
Purpose: The purpose of our study is the establishment of normal database (NDB) from persons (aged 50-80 years) for 3D-SSP analysis of 123I-IMP brain perfusion SPECT image, and we analyzed whether the presence or absence of image correction methods, scatter correction (SC) and attenuation correction (AC), affects the created NDB and 3D-SSP analysis.
Materials and methods: We created NDB from 63 healthy volunteers (32 males and 31 females, aged 50-80 years), and calculated the coefficient of variation for each pixel from the mean value and standard deviation. Next, we compared the visual assessments of the standard deviation images by each image correction method, and the coefficient of variation of SEE analysis in each part of the brain. Furthermore, we examined frontotemporal dementia and healthy volunteers by 3D-SSP analysis, and evaluated the differences of Z-score in the presence or absence of image correction methods.
Results: In NDB, the coefficient of variation was the minimum when SC and AC were not applied and the maximum in periventricular and cerebellum when SC and AC were applied. In Z-score image of 3D-SSP analysis, Z-score of the low value was the maximum when SC and AC were not applied.
Conclusion: It was shown that the results from NDB coefficient of variation and 3D-SSP analysis were affected by the differences of image correction methods. It is important to understand the feature of imaging reconstruction conditions in your own facilities, and evaluate 3D-SSP analysis.
Similar articles
-
Clinical utility of the normal database of 123I-iodoamphetamine brain perfusion single photon emission computed tomography for statistical analysis using computed tomography-based attenuation correction: a multicenter study.Ann Nucl Med. 2019 Nov;33(11):835-841. doi: 10.1007/s12149-019-01395-0. Epub 2019 Aug 14. Ann Nucl Med. 2019. PMID: 31414335
-
Does applying resolution recovery to normal databases confer an advantage over conventional 3D-stereotactic surface projection techniques?Radiol Phys Technol. 2017 Jun;10(2):240-248. doi: 10.1007/s12194-017-0391-8. Epub 2017 Feb 4. Radiol Phys Technol. 2017. PMID: 28161808
-
[Availability of normal database by single photon emission computed tomography system with use of 3 dimensional-stereotactic surface projections].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68(12):1608-16. doi: 10.6009/jjrt.2012_jsrt_68.12.1608. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012. PMID: 23257590 Japanese.
-
Stereotactic statistical imaging analysis of the brain using the easy Z-score imaging system for sharing a normal database.Radiat Med. 2006 Aug;24(7):545-52. doi: 10.1007/s11604-006-0056-8. Radiat Med. 2006. PMID: 17058152 Review.
-
[The statistical imaging analysis in brain using nuclear medicine and FMRI techniques].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2003 May;59(5):594-603. doi: 10.6009/jjrt.kj00000921796. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2003. PMID: 12881687 Review. Japanese. No abstract available.
Cited by
-
Impact of injected dose and acquisition time on a normal database by use of 3D-SSP in SPECT images: quantitative simulation studies.Radiol Phys Technol. 2015 Jul;8(2):224-31. doi: 10.1007/s12194-015-0311-8. Epub 2015 Mar 11. Radiol Phys Technol. 2015. PMID: 25758210
MeSH terms
Substances
LinkOut - more resources
Full Text Sources