Patient-prosthesis mismatch in patients with aortic valve replacement
- PMID: 23404312
- PMCID: PMC3641294
- DOI: 10.1007/s11748-013-0216-6
Patient-prosthesis mismatch in patients with aortic valve replacement
Abstract
Objective: Patient-prosthesis mismatch (PPM) may affect clinical outcomes in patients with aortic valve replacement (AVR). We retrospectively examined the PPM in patients with isolated AVR in the Japan Adult Cardiovascular Surgery Database (JACVSD).
Methods: We examined all patients with isolated AVR between January 1, 2008 and December 31, 2009. The JACVSD data collection form has a total of 255 variables. We defined PPM as an effective orifice area index of ≤ 0.85 m(2)/cm(2).
Results: PPM was observed in 306 of 3,609 cases analyzed, PPM rate was 8.5 %. Body surface area was larger and body mass index was higher in the PPM group than the non-PPM group (P < 0.001). Patients with PPM were older (P = 0.001) and had a higher prevalence of diabetes (P = 0.004), dyslipidemia (P < 0.001), hypertension (P < 0.001), cerebrovascular disease (P = 0.031), old myocardial infarction (P = 0.006), previous percutaneous coronary artery intervention (P = 0.001), coronary artery disease (P = 0.018), and aortic valve stenosis (P < 0.001). Perioperative blood transfusion (P < 0.001) and dialysis (P = 0.005) were more frequent in the PPM group. Postoperative ventilation (P = 0.004) and intensive care unit stay (P = 0.004) were significantly longer in the PPM group.
Conclusions: Age, aortic valve stenosis, dyslipidemia, hypertension, old myocardial infarction, previous percutaneous coronary artery intervention, diabetes mellitus, cerebrovascular disease, and high body mass index were the risk factors for PPM. PPM was not an independent risk factor for short-term mortality.
Similar articles
-
Aortic valve prosthesis-patient mismatch and long-term outcomes: 19-year single-center experience.Ann Thorac Surg. 2013 Sep;96(3):844-50. doi: 10.1016/j.athoracsur.2013.04.075. Epub 2013 Jun 25. Ann Thorac Surg. 2013. PMID: 23810177
-
Impact of prosthesis-patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China.J Cardiothorac Surg. 2017 May 25;12(1):42. doi: 10.1186/s13019-017-0596-2. J Cardiothorac Surg. 2017. PMID: 28545592 Free PMC article.
-
Does patient-prosthesis mismatch influence the results of combined aortic valve replacement and coronary bypass grafting?Kardiol Pol. 2009 Aug;67(8):865-73. Kardiol Pol. 2009. PMID: 19784883
-
Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement.JACC Cardiovasc Imaging. 2016 Aug;9(8):924-33. doi: 10.1016/j.jcmg.2015.10.026. Epub 2016 May 25. JACC Cardiovasc Imaging. 2016. PMID: 27236530 Review.
-
Patient-prosthesis mismatch following aortic valve replacement.Heart. 2019 Mar;105(Suppl 2):s28-s33. doi: 10.1136/heartjnl-2018-313515. Heart. 2019. PMID: 30846522 Review.
Cited by
-
Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement: A meta-analysis.Medicine (Baltimore). 2020 Jun 12;99(24):e20717. doi: 10.1097/MD.0000000000020717. Medicine (Baltimore). 2020. PMID: 32541522 Free PMC article.
-
Mini-aortic valve replacements are not associated with an increased incidence of patient-prosthesis mismatch: a propensity-scored analysis.Gen Thorac Cardiovasc Surg. 2016 Mar;64(3):144-8. doi: 10.1007/s11748-015-0614-z. Epub 2015 Dec 19. Gen Thorac Cardiovasc Surg. 2016. PMID: 26688505
-
Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients.Indian J Thorac Cardiovasc Surg. 2019 Jan;35(1):6-14. doi: 10.1007/s12055-018-0706-3. Epub 2018 Aug 28. Indian J Thorac Cardiovasc Surg. 2019. PMID: 33060963 Free PMC article.
-
Fifteen-year experience with the Bicarbon heart valve prosthesis in a single center.J Cardiothorac Surg. 2015 Jun 28;10:89. doi: 10.1186/s13019-015-0294-x. J Cardiothorac Surg. 2015. PMID: 26123076 Free PMC article.
-
The effect of patient-prosthesis mismatch on survival after aortic and mitral valve replacement: a 10 year, single institution experience.J Cardiothorac Surg. 2019 Dec 6;14(1):214. doi: 10.1186/s13019-019-1034-4. J Cardiothorac Surg. 2019. PMID: 31810475 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources