Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
- PMID: 23404384
- PMCID: PMC3701132
- DOI: 10.1007/s10554-013-0190-1
Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
Abstract
To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutive clinical coronary CTA studies were processed utilizing standard FBP, FBP with 50% simulated dose reduction (FBP50%), and AIDR3D with simulated 50% dose reduction (AIDR50%). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured within 5 regions-of-interest, and image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Compared to FBP, the SNR measured from the AIDR50% images was similar or higher (airway: 38.3 ± 12.7 vs. 38.5 ± 14.5, p = 0.81, fat: 5.5 ± 1.9 vs. 5.4 ± 2.0, p = 0.20, muscle: 3.2 ± 1.2 vs. 3.1 ± 1.3, p = 0.38, aorta: 22.6 ± 9.4 vs. 20.2 ± 9.7, p < 0.0001, liver: 2.7 ± 1.0 vs. 2.3 ± 1.1, p < 0.0001), while the SNR of the FBP50 % images were all lower (p values < 0.0001). The CNR measured from AIDR50% images was also higher than that from the FBP images for the aorta relative to muscle (20.5 ± 9.0 vs. 18.3 ± 9.2, p < 0.0001). The interobserver agreement in the image quality score was excellent (κ = 0.82). The quality score was significantly higher for the AIDR50% images compared to the FBP images (3.6 ± 0.6 vs. 3.3 ± 0.7, p = 0.004). Simulated radiation dose reduction applied to clinical coronary CTA images suggests that a 50% reduction in radiation dose can be achieved with adaptive iterative dose reduction software with image quality that is at least comparable to images acquired at standard radiation exposure and reconstructed with filtered back projection.
Figures




Similar articles
-
Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D).PLoS One. 2015 Nov 23;10(11):e0142185. doi: 10.1371/journal.pone.0142185. eCollection 2015. PLoS One. 2015. PMID: 26599111 Free PMC article.
-
Image quality of adaptive iterative dose reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection.Int J Cardiovasc Imaging. 2013 Mar;29(3):669-76. doi: 10.1007/s10554-012-0113-6. Epub 2012 Aug 26. Int J Cardiovasc Imaging. 2013. PMID: 22923280
-
Reduced radiation exposure for face transplant surgical planning computed tomography angiography.PLoS One. 2013 Apr 26;8(4):e63079. doi: 10.1371/journal.pone.0063079. Print 2013. PLoS One. 2013. PMID: 23638180 Free PMC article.
-
Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction.Int J Cardiovasc Imaging. 2015 Jun;31 Suppl 1:31-8. doi: 10.1007/s10554-014-0570-1. Epub 2014 Nov 21. Int J Cardiovasc Imaging. 2015. PMID: 25414055
-
Iterative reconstruction for coronary CT angiography: finding its way.Int J Cardiovasc Imaging. 2012 Mar;28(3):613-20. doi: 10.1007/s10554-011-9832-3. Epub 2011 Feb 27. Int J Cardiovasc Imaging. 2012. PMID: 21359835 Review.
Cited by
-
Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D.Int J Cardiovasc Imaging. 2015 Jun;31(5):1045-52. doi: 10.1007/s10554-015-0637-7. Epub 2015 Mar 10. Int J Cardiovasc Imaging. 2015. PMID: 25754302
-
Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.Int J Cardiovasc Imaging. 2014 Apr;30(4):683-95. doi: 10.1007/s10554-014-0405-0. Int J Cardiovasc Imaging. 2014. PMID: 24687406 Review. No abstract available.
-
Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality.Eur Radiol. 2014 Oct;24(10):2458-66. doi: 10.1007/s00330-014-3281-z. Epub 2014 Jun 26. Eur Radiol. 2014. PMID: 24965510
-
Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT.Jpn J Radiol. 2014 Jul;32(7):391-6. doi: 10.1007/s11604-014-0321-1. Epub 2014 Apr 28. Jpn J Radiol. 2014. PMID: 24771358
-
Coronary CT angiography using the second-generation 320-detector row CT: assessment of image quality and radiation dose in various heart rates compared with the first-generation scanner.Int J Cardiovasc Imaging. 2013 Oct;29(7):1613-8. doi: 10.1007/s10554-013-0238-2. Epub 2013 May 17. Int J Cardiovasc Imaging. 2013. PMID: 23681500
References
-
- Mark DB, Berman DS, Budoff MJ, Carr JJ, Gerber TC, Hecht HS, Hlatky MA, Hodgson JM, Lauer MS, Miller JM, Morin RL, Mukherjee D, Poon M, Rubin GD, Schwartz RS. ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 expert consensus document on coronary computed tomographic angiography: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. Circulation. 2010;121(22):2509–2543. doi: 10.1161/CIR.0b013e3181d4b618. - DOI - PubMed
-
- Paech DC, Weston AR. A systematic review of the clinical effectiveness of 64-slice or higher computed tomography angiography as an alternative to invasive coronary angiography in the investigation of suspected coronary artery disease. BMC Cardiovasc Disord. 2011;11:32. doi: 10.1186/1471-2261-11-32. - DOI - PMC - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous