Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2013 Jul;190(1):64-9.
doi: 10.1016/j.juro.2013.02.018. Epub 2013 Feb 14.

PCA3 molecular urine test as a predictor of repeat prostate biopsy outcome in men with previous negative biopsies: a prospective multicenter clinical study

Affiliations
Randomized Controlled Trial

PCA3 molecular urine test as a predictor of repeat prostate biopsy outcome in men with previous negative biopsies: a prospective multicenter clinical study

Marc C Gittelman et al. J Urol. 2013 Jul.

Abstract

Purpose: We evaluated the clinical usefulness of the PROGENSA® PCA3 Assay for predicting repeat prostate biopsy outcome.

Materials and methods: Men with at least 1 prior negative prostate biopsy who were scheduled for repeat prostate biopsy based on best clinical judgment were enrolled at 14 centers. Whole blood and post-digital rectal examination urine samples were collected before extended template transrectal biopsy with 12 or more cores. Urinary PCA3 scores and biopsy outcomes were assessed by logistic regression analysis, which also included age, race, serum prostate specific antigen, clinical stage, family history of prostate cancer and the number of previous negative biopsy sessions.

Results: A total of 466 men were included in study and prostate cancer was identified in 21.9%. A PCA3 score cutoff of 25 yielded 77.5% sensitivity, 57.1% specificity, and negative and positive predictive values of 90% and 33.6%, respectively. On multivariable logistic regression men with a PCA3 score of less than 25 were 4.56 times as likely to have a negative repeat biopsy as men with a score of 25 or greater. PCA3 score significantly increased the predictive accuracy of the logistic regression model. At 90% sensitivity adding the PCA3 score to the model increased specificity, and positive and negative predictive values by 22.6%, 6.4% and 7.1%, respectively, relative to the model without the PCA3 score.

Conclusions: The PCA3 score supplements serum prostate specific antigen and other clinical information to provide more accurate prediction of repeat biopsy outcome. Thus, it provides clinicians and patients with independent, clinically useful information to make more informed repeat biopsy decisions.

Trial registration: ClinicalTrials.gov NCT01024959.

PubMed Disclaimer

Publication types

MeSH terms

Associated data