Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2013 Jun;27(3):319-24.
doi: 10.1007/s10877-013-9437-6. Epub 2013 Feb 16.

Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?

Affiliations
Randomized Controlled Trial

Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?

Derya Berk et al. J Clin Monit Comput. 2013 Jun.

Abstract

Arterial cannulation with ultrasound (US) guidance increases the success rate and reduces complications. US-guided vascular access has two main approaches: long axis in-plane (LA-IP) and short axis out-of-plane (SA-OOP) approaches. The purpose of this study was to compare performance time and possible complications between two techniques. After obtaining ethics committee approval and informed patient consent, a prospective and randomized trial was conducted at ASA I-III, patients between the ages of 20-70 years. 108 patients were scheduled for radial arterial cannulaton in patients undergoing elective surgery under general anesthesia. Patients were divided into two groups as LA-IP and SA-OOP approaches with sealed envelope randomized method. After induction of anesthesia, the distance between skin-to-artery and the diameter of radial artery in US-imaging was recorded. The successful cannulation time, the number of attempts, potential complications such as thrombosis, edema, vasospasm, hematoma and posterior wall puncture were recorded. Demographic and hemodynamic parameters were similar in two groups. The diameter and the depth of artery were also similar in both of groups. Cannulation time was shorter in LA-IP Group compared to SA-OOP (24 ± 17 s vs. 47 ± 34 s respectively, p < 0.05). The arterial cannulation by LA-IP approach increased the rate of cannula-insertion success at the first attempt (76 %) compared to SA-OOP approach (51 %). Posterior wall damage during arterial cannulation were found in 30 patients with SA-OOP Group (56 %) and 11 patients with LA-IP Group (20 %), (p < 0.05). In our study, the use of LA-IP approach during US-guided radial artery cannulation has higher success rate at first insertion. We also found LA-IP approach results in shorter cannulation time and decreased the incidence of complications.

PubMed Disclaimer

Comment in

References

    1. Crit Care. 2002 Jun;6(3):199-204 - PubMed
    1. J Clin Anesth. 2006 Mar;18(2):138-41 - PubMed
    1. Am J Emerg Med. 2010 Mar;28(3):343-7 - PubMed
    1. Chest. 2011 Mar;139(3):524-529 - PubMed
    1. Med Ultrason. 2011 Mar;13(1):21-5 - PubMed

Publication types