High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions
- PMID: 23433596
- DOI: 10.1016/j.gie.2013.01.001
High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions
Abstract
Background: Current limitations of EUS-guided FNA include the need for multiple passes and on-site cytology assessment and lack of core specimen. Recently, a new 25-gauge core biopsy needle (PC25) was developed to overcome these limitations.
Objective: To determine the diagnostic yield of EUS-guided FNA aspiration biopsy (FNAB) when using the PC25 needle among patients with solid pancreatic lesions.
Design: Retrospective analysis.
Setting: Academic tertiary referral center.
Patients: Fifty consecutive patients with a solid pancreatic lesion underwent EUS-guided FNAB with PC25.
Interventions: EUS-guided FNAB with PC25.
Main outcome measurements: The primary outcome was the diagnostic yield in single and overall passes of EUS-guided FNAB when using the PC25 needle for pancreatic solid lesions.
Results: Cytologic analysis showed malignancy in 38 patients on the first pass, with a cumulative sensitivity of 83%, 91%, and 96% on passes 1, 2, and 3, respectively. Although visible core was reported in 46 patients (92%), histologic core was seen in 16 patients (32%). Histologic analysis showed malignancy in 29 patients on the first pass, with a cumulative sensitivity of 63% and 87% on pass 1 and passes 1 to 4, respectively. The sensitivity, specificity, and accuracy in combined cytologic and histologic results were 85%, 100%, and 86% for single pass and 96%, 100%, and 96% on multiple passes, respectively. No complications were seen.
Limitations: A retrospective study design at a single center using a single arm.
Conclusion: EUS-guided FNAB with the PC25 needle showed excellent single-pass and overall diagnostic yields. This needle appears to maintain a high cytologic yield, similar to standard 25-gauge FNA needles, while also providing some histologic core tissue.
Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Similar articles
-
Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles.BMC Gastroenterol. 2015 Sep 29;15:122. doi: 10.1186/s12876-015-0352-9. BMC Gastroenterol. 2015. PMID: 26419845 Free PMC article.
-
A pilot study of EUS-guided through-the-needle forceps biopsy (with video).Gastrointest Endosc. 2016 Jul;84(1):158-62. doi: 10.1016/j.gie.2015.12.033. Epub 2016 Jan 6. Gastrointest Endosc. 2016. PMID: 26772889
-
Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study).Gastrointest Endosc. 2015 Jan;81(1):177-85. doi: 10.1016/j.gie.2014.08.040. Epub 2014 Oct 29. Gastrointest Endosc. 2015. PMID: 25440688
-
Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network meta-analysis.Gastrointest Endosc. 2019 Dec;90(6):893-903.e7. doi: 10.1016/j.gie.2019.07.009. Epub 2019 Jul 13. Gastrointest Endosc. 2019. PMID: 31310744
-
The diagnostic accuracy of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions: a meta-analysis.Endoscopy. 2013;45(2):86-92. doi: 10.1055/s-0032-1325992. Epub 2013 Jan 10. Endoscopy. 2013. PMID: 23307148 Review.
Cited by
-
Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses.PLoS One. 2016 May 5;11(5):e0154401. doi: 10.1371/journal.pone.0154401. eCollection 2016. PLoS One. 2016. PMID: 27149404 Free PMC article. Clinical Trial.
-
Endoscopic ultrasound-guided fine-needle aspiration for pancreatic cystic lesions: a comprehensive review.J Med Ultrason (2001). 2024 Apr;51(2):219-226. doi: 10.1007/s10396-023-01389-6. Epub 2023 Dec 5. J Med Ultrason (2001). 2024. PMID: 38051460 Review.
-
Procore and flexible 19 gauge needle can replace trucut biopsy needle?Clin Endosc. 2013 Sep;46(5):503-5. doi: 10.5946/ce.2013.46.5.503. Epub 2013 Sep 30. Clin Endosc. 2013. PMID: 24143312 Free PMC article. Review.
-
Agreement on endoscopic ultrasonography-guided tissue specimens: Comparing a 20-G fine-needle biopsy to a 25-G fine-needle aspiration needle among academic and non-academic pathologists.Dig Endosc. 2019 Nov;31(6):690-697. doi: 10.1111/den.13424. Epub 2019 Jul 10. Dig Endosc. 2019. PMID: 31290176 Free PMC article. Clinical Trial.
-
Endoscopic Ultrasound in the Diagnosis and Staging of Pancreatic Cancer.GE Port J Gastroenterol. 2015 Jul 2;22(4):161-171. doi: 10.1016/j.jpge.2015.04.007. eCollection 2015 Jul-Aug. GE Port J Gastroenterol. 2015. PMID: 28868399 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical