Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Sep;15(9):1273-9.
doi: 10.1093/europace/eut032. Epub 2013 Feb 24.

Cardiac resynchronization therapy-defibrillator improves long-term survival compared with cardiac resynchronization therapy-pacemaker in patients with a class IA indication for cardiac resynchronization therapy: data from the Contak Italian Registry

Affiliations
Comparative Study

Cardiac resynchronization therapy-defibrillator improves long-term survival compared with cardiac resynchronization therapy-pacemaker in patients with a class IA indication for cardiac resynchronization therapy: data from the Contak Italian Registry

Giovanni Morani et al. Europace. 2013 Sep.

Abstract

Aims: In candidates for cardiac resynchronization therapy (CRT), the choice between pacemaker (CRT-P) and defibrillator (CRT-D) implantation is still debated. We compared the long-term prognosis of patients who received CRT-D or CRT-P according to class IA recommendations of the European Society of Cardiology (ESC) and who were enrolled in a multicentre prospective registry.

Methods and results: A total of 620 heart failure patients underwent successful implantation of a CRT device and were enrolled in the Contak Italian Registry. This analysis included 266 patients who received a CRT-D and 108 who received a CRT-P according to class IA ESC indications. Their survival status was verified after a median follow-up of 55 months. During follow-up, 73 CRT-D and 44 CRT-P patients died (rate 6.6 vs. 10.4%/year; log-rank test, P = 0.020). Patients receiving CRT-P were predominantly older, female, had no history of life-threatening ventricular arrhythmias, and more frequently presented non-ischaemic aetiology of heart failure, longer QRS durations, and worse renal function. However, the only independent predictor of death from any cause was the use of CRT-P (hazard ratio, 1.97; 95% confidence interval, 1.21-3.16; P = 0.007).

Conclusion: The implantation of CRT-D, rather than CRT-P, may be preferable in patients presenting with current class IA ESC indications for CRT. Indeed, CRT-D resulted in greater long-term survival and was independently associated with a better prognosis.

Keywords: Cardiac resynchronization therapy; Heart Failure; ICD; Mortality; Pacemaker.

PubMed Disclaimer

MeSH terms