Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Feb 15;185(1):1-9.
doi: 10.1016/0003-2697(90)90246-6.

Versatile stable isotope technique for the measurement of amino acids and keto acids: comparison with radioactive isotope and its use in measuring in vivo disposal rates

Affiliations

Versatile stable isotope technique for the measurement of amino acids and keto acids: comparison with radioactive isotope and its use in measuring in vivo disposal rates

G L Loy et al. Anal Biochem. .

Abstract

Tracer methods using both carbon-13 and -14 have been utilized for determination of ovine fetal amino acid disposal and the results compared in seven animals. We infused [1-13C]leucine simultaneously with [1-14C]leucine into the fetal circulation of pregnant sheep chronically catheterized during late gestation. Radioactive and stable isotope enrichments of leucine (Leu) and stable isotope enrichments of ketoisocaproic acid (KIC) in the umbilical artery and vein and the maternal artery and uterine vein were measured. Stable isotope enrichments and concentrations of both Leu and KIC were determined from a single 0.2-ml sample by the use of internal standards and electron ionization GC/MS analysis after a simple isolation and derivatization procedure. The KIC/Leu enrichment ratio was measured for the first time in fetal arterial plasma and was 0.66 +/- 0.05 (SE). Fetal leucine disposal rate was 9.0 +/- 0.5 (SE) micron/min/kg. Disposal rates determined by stable isotopes were not different from those determined by radioactive isotopes. The GC/MS stable isotope method provided higher precision in both leucine concentration and enrichment measurements and has been shown to be a general method for the determination of concentration and isotopic enrichment of other amino acids and their corresponding keto acids. Furthermore, this method is ideally suited to clinical studies where large numbers of samples of rather small volume can easily be studied with a short turnaround time.

PubMed Disclaimer

Publication types

LinkOut - more resources