Brain-computer interfaces using capacitive measurement of visual or auditory steady-state responses
- PMID: 23448913
- DOI: 10.1088/1741-2560/10/2/024001
Brain-computer interfaces using capacitive measurement of visual or auditory steady-state responses
Abstract
Objective: Brain-computer interface (BCI) technologies have been intensely studied to provide alternative communication tools entirely independent of neuromuscular activities. Current BCI technologies use electroencephalogram (EEG) acquisition methods that require unpleasant gel injections, impractical preparations and clean-up procedures. The next generation of BCI technologies requires practical, user-friendly, nonintrusive EEG platforms in order to facilitate the application of laboratory work in real-world settings.
Approach: A capacitive electrode that does not require an electrolytic gel or direct electrode-scalp contact is a potential alternative to the conventional wet electrode in future BCI systems. We have proposed a new capacitive EEG electrode that contains a conductive polymer-sensing surface, which enhances electrode performance. This paper presents results from five subjects who exhibited visual or auditory steady-state responses according to BCI using these new capacitive electrodes. The steady-state visual evoked potential (SSVEP) spelling system and the auditory steady-state response (ASSR) binary decision system were employed.
Main results: Offline tests demonstrated BCI performance high enough to be used in a BCI system (accuracy: 95.2%, ITR: 19.91 bpm for SSVEP BCI (6 s), accuracy: 82.6%, ITR: 1.48 bpm for ASSR BCI (14 s)) with the analysis time being slightly longer than that when wet electrodes were employed with the same BCI system (accuracy: 91.2%, ITR: 25.79 bpm for SSVEP BCI (4 s), accuracy: 81.3%, ITR: 1.57 bpm for ASSR BCI (12 s)). Subjects performed online BCI under the SSVEP paradigm in copy spelling mode and under the ASSR paradigm in selective attention mode with a mean information transfer rate (ITR) of 17.78 ± 2.08 and 0.7 ± 0.24 bpm, respectively.
Significance: The results of these experiments demonstrate the feasibility of using our capacitive EEG electrode in BCI systems. This capacitive electrode may become a flexible and non-intrusive tool fit for various applications in the next generation of BCI technologies.
Similar articles
-
Enhancing the Usability of Brain-Computer Interface Systems.Comput Intell Neurosci. 2019 Jun 16;2019:5427154. doi: 10.1155/2019/5427154. eCollection 2019. Comput Intell Neurosci. 2019. PMID: 31316556 Free PMC article. Review.
-
Dry and noncontact EEG sensors for mobile brain-computer interfaces.IEEE Trans Neural Syst Rehabil Eng. 2012 Mar;20(2):228-35. doi: 10.1109/TNSRE.2011.2174652. Epub 2011 Dec 12. IEEE Trans Neural Syst Rehabil Eng. 2012. PMID: 22180514
-
A hybrid BCI speller paradigm combining P300 potential and the SSVEP blocking feature.J Neural Eng. 2013 Apr;10(2):026001. doi: 10.1088/1741-2560/10/2/026001. Epub 2013 Jan 31. J Neural Eng. 2013. PMID: 23369924
-
Classification of binary intentions for individuals with impaired oculomotor function: 'eyes-closed' SSVEP-based brain-computer interface (BCI).J Neural Eng. 2013 Apr;10(2):026021. doi: 10.1088/1741-2560/10/2/026021. Epub 2013 Mar 26. J Neural Eng. 2013. PMID: 23528484
-
Visual and auditory brain-computer interfaces.IEEE Trans Biomed Eng. 2014 May;61(5):1436-47. doi: 10.1109/TBME.2014.2300164. IEEE Trans Biomed Eng. 2014. PMID: 24759277 Review.
Cited by
-
Brain-Computer Interface-Controlled Exoskeletons in Clinical Neurorehabilitation: Ready or Not?Neurorehabil Neural Repair. 2022 Dec;36(12):747-756. doi: 10.1177/15459683221138751. Epub 2022 Nov 25. Neurorehabil Neural Repair. 2022. PMID: 36426541 Free PMC article. Review.
-
Challenges in clinical applications of brain computer interfaces in individuals with spinal cord injury.Front Neuroeng. 2014 Sep 24;7:38. doi: 10.3389/fneng.2014.00038. eCollection 2014. Front Neuroeng. 2014. PMID: 25309420 Free PMC article. Review.
-
Enhancing the Usability of Brain-Computer Interface Systems.Comput Intell Neurosci. 2019 Jun 16;2019:5427154. doi: 10.1155/2019/5427154. eCollection 2019. Comput Intell Neurosci. 2019. PMID: 31316556 Free PMC article. Review.
-
Effects of spectral smearing of stimuli on the performance of auditory steady-state response-based brain-computer interface.Cogn Neurodyn. 2017 Dec;11(6):515-527. doi: 10.1007/s11571-017-9448-y. Epub 2017 Jul 31. Cogn Neurodyn. 2017. PMID: 29147144 Free PMC article.
-
Two-Wired Active Spring-Loaded Dry Electrodes for EEG Measurements.Sensors (Basel). 2019 Oct 21;19(20):4572. doi: 10.3390/s19204572. Sensors (Basel). 2019. PMID: 31640169 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources