In vitro electro-mechanical characterization of human knee articular cartilage of different degeneration levels: a comparison with ICRS and Mankin scores
- PMID: 23477790
- DOI: 10.1016/j.jbiomech.2013.02.004
In vitro electro-mechanical characterization of human knee articular cartilage of different degeneration levels: a comparison with ICRS and Mankin scores
Abstract
In the present study, the electro-mechanical properties of human knee articular cartilage were measured in vitro. An arthroscopic measurement tool was used to measure streaming potential integral (SPI), after which creep indentation tests were performed. Additionally, degradation level of the tissue was determined in accordance with the International Cartilage Repair Society (ICRS score), and hematoxylin/eosin and safranin O staining were performed to determine the Mankin score. Mechanical test results were evaluated both analytically and by means of a finite-element-optimized parameter identification procedure. The SPI was then correlated with poroelastic E modulus (r=0.563, p<0.008, n=22), natural logarithm of hydraulic permeability (r=0.374, p<0.095, n=22) and cartilage degeneration scores (ICRS and Mankin) (r=-0.749, p<0.000, n=22 and r=-0.409, p<0.059, n=22 respectively).
Copyright © 2013 Elsevier Ltd. All rights reserved.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources