[Clinical value of ECG-gated dual-source computed tomography and angiography in assessing coarctation of aorta]
- PMID: 23488145
[Clinical value of ECG-gated dual-source computed tomography and angiography in assessing coarctation of aorta]
Abstract
The purpose of this study was to explore the clinical value of ECG-gated dual-source CT angiography (DSCTA) in evaluating coarctation of aorta (CoA). 23 patients suspected with CoA underwent DSCTA and transthoracic echocardiography (TTE). Surgical results were taken as reference standard. 23 patients were diagnosed with CoA, 12 cases had focal stenosis of aorta, while 11 had tubular stenosis. 19 cases were associated with other cardiovascular malformations, including 5 cases of hypoplastic aortic arch, 5 of patent ductus arteriosus, 10 of ventricular septal defect, 2 of bicuspid aortic valve, 4 of collateral arteries, 2 of aberrant left subclavian artery and 2 of persistent left superior vena cava, respectively. The mean diameter of stenotic segment of aorta was (7.0 +/- 3.7) mm. In 9 patients with tubular CoA, the diameter and length of stenotic segment of aorta were (6.2 +/- 7. 3) mm and (29.2 +/- 5.9) mm, respectively. The accuracies of DSCTA and TTE in the diagnosis of CoA were 100% and 91.3% (P > 0.05), respectively. It is well concluded that ECG-gated DSCTA could accurately evaluate CoA and associated cardiovascular malformations, and provide detailed anatomic information before surgery.
Similar articles
-
The value of low-dose prospective ECG-gated dual-source CT angiography in the diagnosis of coarctation of the aorta in infants and children.Clin Radiol. 2012 Aug;67(8):738-45. doi: 10.1016/j.crad.2011.12.007. Epub 2012 Feb 14. Clin Radiol. 2012. PMID: 22336668
-
[Clinical value of ECG-gated dual-source computed tomography and angiography in assessing pulmonary atresia with ventricular septal defect].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2012 Dec;29(6):1084-8. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2012. PMID: 23469535 Chinese.
-
Accuracy, image quality, and radiation dose of prospectively ECG-triggered high-pitch dual-source CT angiography in infants and children with complex coarctation of the aorta.Acad Radiol. 2014 Oct;21(10):1248-54. doi: 10.1016/j.acra.2014.04.019. Epub 2014 Aug 2. Acad Radiol. 2014. PMID: 25097011 Clinical Trial.
-
Coarctation of aorta--intervention from neonates to adult life.Indian Heart J. 2008 Nov-Dec;60(4 Suppl D):D22-33. Indian Heart J. 2008. PMID: 19845083 Review.
-
Diagnosis, imaging and clinical management of aortic coarctation.Heart. 2017 Aug;103(15):1148-1155. doi: 10.1136/heartjnl-2017-311173. Epub 2017 Apr 4. Heart. 2017. PMID: 28377475 Review.