Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Feb;6(2):206-16.
doi: 10.1016/j.jcmg.2012.10.016.

Comparison of different TEE-guided thrombolytic regimens for prosthetic valve thrombosis: the TROIA trial

Affiliations
Free article
Comparative Study

Comparison of different TEE-guided thrombolytic regimens for prosthetic valve thrombosis: the TROIA trial

Mehmet Özkan et al. JACC Cardiovasc Imaging. 2013 Feb.
Free article

Abstract

Objectives: The aim of this prospective study was to identify the most effective and safest regimen among different thrombolytic treatment strategies.

Background: The best treatment strategies for prosthetic valve thrombosis have been controversial.

Methods: Transesophageal echocardiography-guided thrombolytic treatment was administered to 182 consecutive patients with prosthetic valve thrombosis in 220 different episodes (156 women; mean age, 43.2 ± 13.06 years) between 1993 and 2009 at a single center. These regimens chronologically included rapid (Group I), slow (Group II) streptokinase, high-dose (100 mg) tissue plasminogen activator (t-PA) (Group III), a half-dose (50 mg) and slow infusion (6 h) of t-PA without bolus (Group IV), and a low dose (25 mg) and slow infusion (6 h) of t-PA without bolus (Group V). The endpoints were thrombolytic success, in-hospital mortality, and nonfatal complication rates.

Results: The overall success rate in the whole series was 83.2%; it did not differ significantly among Groups I through V (68.8%, 85.4%, 75%, 81.5%, and 85.5%, respectively; p = 0.46). The overall complication rate in the whole series was 18.6%. Although the overall complication rate was similar among Groups I through IV (37.5%, 24.4 %, 33.3%, and 29.6%, respectively; p > 0.05 for each comparison), it was significantly lower in Group V (10.5%, p < 0.05 for each). The combined rates of mortality and nonfatal major complications were also lower in Group V than in the other groups, with all differences significant except for comparison of Groups IV and V. By multivariate analysis, the predictors of combined mortality plus nonfatal major complications were any thrombolytic therapy regimen other than Group V (odds ratios for Groups I through IV: 8.2, 3.8, 8.1, and 4.1, respectively; p < 0.05 for each) and a history of stroke/transient ischemic attack (odds ratio: 3.5, p = 0.011). In addition, there was no mortality in Group V.

Conclusions: Low-dose slow infusion of t-PA repeated as needed without a bolus provides effective and safe thrombolysis in patients with prosthetic valve thrombosis. (Comparison of Different TRansesophageal Echocardiography Guided thrOmbolytic Regimens for prosthetIc vAlve Thrombosis; NCT01451320).