Microbial and endotoxin contamination in water and dialysate in the central United States
- PMID: 2350260
- DOI: 10.1111/j.1525-1594.1990.tb01601.x
Microbial and endotoxin contamination in water and dialysate in the central United States
Abstract
The purified water supplies and randomly selected dialysates of 51 chronic and acute dialysis centers in the central United States were surveyed to assess the relative risks to dialysis patients from microbial and endotoxin contamination. A culture medium more sensitive than those generally employed in routine quality assurance assays was used for recovery of bacteria from water. With this medium, 35.3% of the water samples and 19% of the dialysate samples were out of compliance with the Association for the Advancement of Medical Instrumentation (AAMI) standards: 200 and 2,000 colony forming units (CFU)/ml, respectively. There was no correlation observed between the type of water purification system or the frequency of disinfection of the system and the bacterial and endotoxin contamination levels. There was also no correlation found between the bacterial and fungal CFU per ml and the endotoxin concentration per ml (EU/ml). It is recommended that more sensitive culturing methods be used to provide adequate bacterial monitoring of dialysate center water supplies. Dialysis centers should monitor endotoxin in dialysate on a regular schedule and immediately after any endotoxemic-like patient reactions. Yeast and fungi were observed in 10% and 64% of the water systems, respectively. Dialysate was contaminated by yeast and fungi in 30% and 70% of the centers, respectively. The concentrations of these microbes in both fluids were much lower than bacteria. However, they were observed often enough to warrant further investigation of their impact on the well-being of dialysis patients.
Similar articles
-
Endotoxin and bacterial contamination of dialysis center water and dialysate; a cross sectional survey.Int J Artif Organs. 1990 Jan;13(1):39-43. Int J Artif Organs. 1990. PMID: 2394493
-
Contamination of dialysis water and dialysate. A survey of 30 centers.ASAIO J. 1994 Oct-Dec;40(4):1012-6. ASAIO J. 1994. PMID: 7858320
-
Dialysate contamination and back filtration may limit the use of high-flux dialysis membranes.ASAIO Trans. 1989 Jul-Sep;35(3):519-22. doi: 10.1097/00002480-198907000-00112. ASAIO Trans. 1989. PMID: 2597523
-
Microbiological and endotoxin assays of hemodialysis fluids.Adv Ren Replace Ther. 1995 Jan;2(1):70-9. doi: 10.1016/s1073-4449(12)80073-2. Adv Ren Replace Ther. 1995. PMID: 7614339 Review.
-
Should ultra-pure dialysate be mandatory?Nephrol Dial Transplant. 2000;15 Suppl 1:55-9. doi: 10.1093/oxfordjournals.ndt.a027965. Nephrol Dial Transplant. 2000. PMID: 10737168 Review. No abstract available.
Cited by
-
Bacteriological Quality of Treated Water and Dialysate in Haemodialysis Unit of A Tertiary Care Hospital.J Clin Diagn Res. 2015 Oct;9(10):DC14-6. doi: 10.7860/JCDR/2015/14681.6692. Epub 2015 Oct 1. J Clin Diagn Res. 2015. PMID: 26557519 Free PMC article.
-
Endotoxin-Retentive Filters for the Online Preparation of Ultrapure Dialysis Fluid and Non-Pyrogenic Substitution Fluid: A Critical Review and Reference Guide.Membranes (Basel). 2025 Feb 5;15(2):51. doi: 10.3390/membranes15020051. Membranes (Basel). 2025. PMID: 39997677 Free PMC article. Review.
-
Methods for Sterilizing Clinically Relevant Wear Particles Isolated from Metal-on-Metal Hip Implants.Sci Rep. 2018 Feb 5;8(1):2384. doi: 10.1038/s41598-017-18239-4. Sci Rep. 2018. PMID: 29402892 Free PMC article.
-
Comparison of flow cytometry and heterotrophic plate count methods for dialysis water microbial monitoring.Sci Rep. 2025 Apr 14;15(1):12809. doi: 10.1038/s41598-025-96597-0. Sci Rep. 2025. PMID: 40229402 Free PMC article.
-
Water quality in conventional and home haemodialysis.Nat Rev Nephrol. 2012 Dec;8(12):725-34. doi: 10.1038/nrneph.2012.241. Epub 2012 Oct 23. Nat Rev Nephrol. 2012. PMID: 23090444 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources