Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2013 Aug;216(5):541-52.
doi: 10.1016/j.ijheh.2013.01.008. Epub 2013 Mar 16.

HUMN project initiative and review of validation, quality control and prospects for further development of automated micronucleus assays using image cytometry systems

Affiliations
Review

HUMN project initiative and review of validation, quality control and prospects for further development of automated micronucleus assays using image cytometry systems

Michael Fenech et al. Int J Hyg Environ Health. 2013 Aug.

Abstract

The use of micronucleus (MN) assays in in vitro genetic toxicology testing, radiation biodosimetry and population biomonitoring to study the genotoxic impacts of environment gene-interactions has steadily increased over the past two decades. As a consequence there has been a strong interest in developing automated systems to score micronuclei, a biomarker of chromosome breakage or loss, in mammalian and human cells. This paper summarises the outcomes of a workshop on this topic, organised by the HUMN project, at the 6th International Conference on Environmental Mutagenesis in Human Populations at Doha, Qatar, 2012. The aim of this paper is to summarise the outcomes of the workshop with respect to the set objectives which were: (i) Review current developments in automation of micronucleus assays by image cytometry; (ii) define the performance characteristics of automated MN scoring using image cytometry and methods of assessment for instrument validation and quality control and (iii) discuss the design of inter-laboratory comparisons and standardisation of micronucleus assays using automated image cytometry systems. It is evident that automated scoring of micronuclei by automated image cytometry using different commercially available platforms [e.g. Metafer (MetaSystems), Pathfinder™ (IMSTAR), iCyte(®) (Compucyte)], particularly for lymphocytes, is at a mature stage of development with good agreement between visual and automated scoring across systems (correlation factors ranging from 0.58 to 0.99). However, a standardised system of validation and calibration is required to enable more reliable comparison of data across laboratories and across platforms. This review identifies recent progress, important limitations and steps that need to be taken into account to enable the successful universal implementation of automated micronucleus assays by image cytometry.

Keywords: Automation; Cytokinesis-block; Image cytometry; Lymphocytes; Micronucleus.

PubMed Disclaimer

Publication types

LinkOut - more resources