Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2013 Apr;6(4):369-76.
doi: 10.1016/j.jcin.2012.11.009. Epub 2013 Mar 20.

Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses

Affiliations
Free article
Randomized Controlled Trial

Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses

Jung-Sun Kim et al. JACC Cardiovasc Interv. 2013 Apr.
Free article

Abstract

Objectives: This study sought to assess the impact of intravascular ultrasound (IVUS) guidance on clinical outcomes following drug-eluting stent implantation when treating long lesions.

Background: The role of IVUS guidance when treating long lesions has been tested during bare-metal stent, but not during drug-eluting stent, implantation.

Methods: A total of 543 patients treated with stents ≥ 28 mm in length were randomly assigned to IVUS guidance (n = 269) versus angiography guidance (n = 274). The primary endpoint was a composite of major adverse cardiac events (MACE), including cardiovascular death, myocardial infarction, target vessel revascularization, or stent thrombosis at 1 year following intervention.

Results: In the intention-to-treat analysis, total stent length was 32.4 mm in the IVUS-guided arm versus 32.3 mm in angiography-guided arm (p = 0.84). Adjunct post-dilation was more frequently performed in the IVUS-guided arm (54.6% vs. 44.5%, p = 0.03); post-intervention minimal lumen diameters were similar (2.55 vs. 2.55 mm, respectively, p = 0.50); and MACE occurred in 12 (4.5%) patients in IVUS-guided arm and in 20 (7.3%) patients in the angiography-guided arm (p = 0.16). However, among the 269 patients assigned to IVUS guidance, IVUS was not used in 13 patients (4.8%); conversely, in 274 patients assigned to angiography alone, 41 patients (15.0%) were treated with IVUS guidance. Therefore, in a per-protocol analysis according to actual IVUS usage, minimum lumen diameter was larger (2.58 vs. 2.51 mm, p = 0.04), and MACE rates were lower: 4.0% in the IVUS-guided arm versus 8.1% in the angiography-guided arm (p = 0.048).

Conclusions: A strategy of routine IVUS for drug-eluting stent implantation in long lesions did not improve the 1-year MACE rates. The IVUS use per operator decision was associated with improved results. (A New Strategy Regarding Discontinuation of Dual Antiplatelet; NCT01145079).

PubMed Disclaimer

Publication types

MeSH terms

Associated data

LinkOut - more resources