Diagnostic performance of (99m)Tc-MIBI scan in predicting the malignancy of thyroid nodules: a meta-analysis
- PMID: 23529672
- DOI: 10.1007/s12020-013-9932-z
Diagnostic performance of (99m)Tc-MIBI scan in predicting the malignancy of thyroid nodules: a meta-analysis
Abstract
Several studies have investigated the diagnostic performance of (99m)Tc-MIBI scan in the evaluation of thyroid nodules suspicious for malignancy with conflicting results. The aim of our study is to meta-analyze published data on this topic. A comprehensive literature search of studies published through December 2012 regarding the diagnostic performance of (99m)Tc-MIBI scan in the evaluation of thyroid nodules suspicious for malignancy was carried out. Pooled sensitivity and specificity of (99m)Tc-MIBI scan on a per lesion-based analysis and the area under the ROC curve were calculated. Pathological reports of thyroid nodules were considered as reference standard. Twenty-one studies were included in the meta-analysis. Pooled sensitivity and specificity of (99m)Tc-MIBI scan in detecting malignant thyroid nodules were 85.1 % [95 % confidence interval (95 % CI): 81.1-88.5 %] and 45.7 % (95 % CI: 42.7-48.7 %), respectively, on a per lesion-based analysis, irrespective of eventual results of previous technetium pertechnetate ((99m)TcO4) or iodine-123 ((123)I) scan. The area under the ROC curve was 0.78. A sub-analysis restricted to data on hypofunctioning nodules on (99m)TcO4 or (123)I scans was performed: pooled sensitivity and specificity of (99m)Tc-MIBI scan in these nodules were 82.1 % (95 % CI: 77.2-86.3 %) and 62.8 % (95 % CI: 58.9-66.7 %), respectively, on a per lesion-based analysis. The area under the ROC curve was 0.81. (99m)Tc-MIBI scan is a sensitive diagnostic tool in predicting the malignancy of thyroid nodules. Therefore, this imaging method could be helpful in patients with thyroid nodules in which malignancy is suspected on the basis of conventional diagnostic techniques. Higher specificity can be reached when hypofunctioning thyroid nodules are considered.
Similar articles
-
The role of technetium-99m methoxyisobutylisonitrile scintigraphy in the differential diagnosis of cold thyroid nodules.Eur J Nucl Med. 1999 Aug;26(8):798-803. doi: 10.1007/s002590050451. Eur J Nucl Med. 1999. PMID: 10436190
-
Diagnostic Performance of Technetium-99m Methoxy-Isobutyl-Isonitrile for Differentiation of Malignant Thyroid Nodules: A Systematic Review and Meta-Analysis.Thyroid. 2018 Oct;28(10):1339-1348. doi: 10.1089/thy.2018.0072. Thyroid. 2018. PMID: 30129898
-
(99m)Tc-sestamibi scanning in thyroid nodules with nondiagnostic cytology.Head Neck. 2010 May;32(5):607-11. doi: 10.1002/hed.21229. Head Neck. 2010. PMID: 19693945
-
Quantitative dual isotope 123iodine/99mTc-MIBI scintigraphy: A new approach to rule out malignancy in thyroid nodules.Ann Endocrinol (Paris). 2021 Apr;82(2):83-91. doi: 10.1016/j.ando.2021.03.003. Epub 2021 Mar 13. Ann Endocrinol (Paris). 2021. PMID: 33727116
-
[99mTc]MIBI scintigraphy in a patient with thyroid follicular neoplasm: a case report and review of literature.Nucl Med Rev Cent East Eur. 2021;24(2):118-119. doi: 10.5603/NMR.2021.0028. Nucl Med Rev Cent East Eur. 2021. PMID: 34382681 Review.
Cited by
-
Clinical characteristics as predictors of malignancy in patients with indeterminate thyroid cytology: a meta-analysis.Endocrine. 2014 May;46(1):52-9. doi: 10.1007/s12020-013-0057-1. Epub 2013 Oct 3. Endocrine. 2014. PMID: 24197803 Review.
-
Differentiating malignant from benign thyroid nodules with indeterminate cytology by 99mTc-MIBI scan: a new quantitative method for improving diagnostic accuracy.Sci Rep. 2017 Jul 21;7(1):6147. doi: 10.1038/s41598-017-06603-3. Sci Rep. 2017. PMID: 28733644 Free PMC article.
-
99mTc-MIBI imaging in thyroid nodules: is it useful?Endocrine. 2014 May;46(1):1-2. doi: 10.1007/s12020-013-0051-7. Epub 2014 Feb 28. Endocrine. 2014. PMID: 24577805 No abstract available.
-
Molecular imaging with (99m)Tc-MIBI and molecular testing for mutations in differentiating benign from malignant follicular neoplasm: a prospective comparison.Eur J Nucl Med Mol Imaging. 2016 Jun;43(6):1018-26. doi: 10.1007/s00259-015-3285-1. Epub 2015 Dec 23. Eur J Nucl Med Mol Imaging. 2016. PMID: 26695504 Free PMC article. Clinical Trial.
-
Cost-effectiveness of (99m)Tc-MIBI in the evaluation of thyroid nodules for malignancy: a new lease of life for an old radiopharmaceutical?Eur J Nucl Med Mol Imaging. 2014 Jan;41(1):102-4. doi: 10.1007/s00259-013-2583-8. Epub 2013 Oct 11. Eur J Nucl Med Mol Imaging. 2014. PMID: 24114005 No abstract available.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical