Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
- PMID: 2353088
- DOI: 10.1148/radiology.176.1.2353088
Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
Abstract
Continuous computed tomographic (CT) scanning of organ volumes during a single breath hold was studied. The authors modified the table feed mechanism of a continuously rotating CT scanner to allow patient transport at low, but accurately controlled, speeds (0.1-11.0 mm/sec) during continuous 1-second scanning. An algorithm was designed to reconstruct artifact-free images for arbitrary table positions from the helical data by interpolating between adjacent scans. Section sensitivity profiles were enlarged; the section width for a 10-mm section and a speed of 10.0 mm/sec was increased by a factor of 1.3, compared with the nominal value. Clinical examples were presented for studies of lung nodules and studies enhanced with contrast medium. Major advantages are the possibility of continuous scanning of extended volumes within a breath-hold period and retrospective, arbitrary selection of anatomic levels.
Similar articles
-
Lung: spiral volumetric CT with single-breath-hold technique.Radiology. 1990 Sep;176(3):864-7. doi: 10.1148/radiology.176.3.2389050. Radiology. 1990. PMID: 2389050
-
Spiral volumetric CT as a routine technique for thoracic imaging.J Thorac Imaging. 1993 Fall;8(4):316-20. doi: 10.1097/00005382-199323000-00010. J Thorac Imaging. 1993. PMID: 8246332
-
[Spiral computed tomography in the diagnosis and staging of bronchopulmonary carcinoma].Chir Ital. 1995;47(3):13-7. Chir Ital. 1995. PMID: 8964092 Review. Italian.
-
Helical computed tomography scanning of the thorax and abdomen.Jpn J Clin Oncol. 1993 Jun;23(3):156-61. Jpn J Clin Oncol. 1993. PMID: 8394471
-
Spiral CT of the thorax.Semin Ultrasound CT MR. 1994 Apr;15(2):90-106. doi: 10.1016/s0887-2171(05)80092-7. Semin Ultrasound CT MR. 1994. PMID: 8198823 Review.
Cited by
-
Progress of CT aortic angiography combined with coronary artery in the evaluation of acute aortic syndrome.Front Cardiovasc Med. 2022 Nov 21;9:1036982. doi: 10.3389/fcvm.2022.1036982. eCollection 2022. Front Cardiovasc Med. 2022. PMID: 36479572 Free PMC article. Review.
-
Integrated presentation of multimodal brain images.Brain Topogr. 1992 Winter;5(2):135-45. doi: 10.1007/BF01129041. Brain Topogr. 1992. PMID: 1489642 Review.
-
Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations.Front Med. 2011 Sep;5(3):254-70. doi: 10.1007/s11684-011-0153-7. Epub 2011 Oct 2. Front Med. 2011. PMID: 21964707 Review.
-
Feasible Dose Reduction in Routine Chest Computed Tomography Maintaining Constant Image Quality Using the Last Three Scanner Generations: From Filtered Back Projection to Sinogram-affirmed Iterative Reconstruction and Impact of the Novel Fully Integrated Detector Design Minimizing Electronic Noise.J Clin Imaging Sci. 2014 Jul 31;4:38. doi: 10.4103/2156-7514.137826. eCollection 2014. J Clin Imaging Sci. 2014. PMID: 25161807 Free PMC article.
-
Pediatric craniofacial surgery: comparison of milling and stereolithography for 3D model manufacturing.Pediatr Radiol. 1992;22(6):458-60. doi: 10.1007/BF02013512. Pediatr Radiol. 1992. PMID: 1437375
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical