Potential toxicity from prolonged anesthesia: a case report of a thirty-hour anesthetic
- PMID: 2354059
- DOI: 10.1016/0952-8180(90)90095-k
Potential toxicity from prolonged anesthesia: a case report of a thirty-hour anesthetic
Abstract
Selection of anesthetics for prolonged administration must include consideration of potential toxicity resulting from extended exposure. This report deals with a patient undergoing a 30-hour anesthetic that included nitrous oxide (N2O) and isoflurane (9.7 MAC-hours). Serial serum inorganic fluoride levels obtained in the perioperative period demonstrated a peak fluoride level of 12.6 mumols occurring 27 hours after isoflurane was discontinued. Although higher than previously reported fluoride levels following isoflurane anesthesia in healthy adults (4 mumols), the current results are below those levels associated with renal abnormalities after prolonged enflurane anesthesia (34 mumols). In addition to outlining basic care guidelines for patients undergoing a prolonged anesthetic, this report discusses potential toxicity from prolonged exposure to both N2O and isoflurane. It concludes that isoflurane can be tolerated in doses up to 10 MAC-hours without fluoride toxicity but cautions against the use of N2O for periods longer than 24 hours.
Comment in
-
Does anesthetic technique influence cancer?J Clin Anesth. 2012 Feb;24(1):1-2. doi: 10.1016/j.jclinane.2011.10.001. Epub 2011 Dec 6. J Clin Anesth. 2012. PMID: 22154093 No abstract available.
Similar articles
-
Stress hormone changes in general anesthesia of long duration: isoflurane-nitrous oxide vs sevoflurane-nitrous oxide anesthesia.J Clin Anesth. 2005 Dec;17(8):586-91. doi: 10.1016/j.jclinane.2005.03.009. J Clin Anesth. 2005. PMID: 16427527 Clinical Trial.
-
Comparison of induction, maintenance, and recovery characteristics of sevoflurane-N2O and propofol-sevoflurane-N2O with propofol-isoflurane-N2O anesthesia.Anesth Analg. 1992 Feb;74(2):253-9. doi: 10.1213/00000539-199202000-00015. Anesth Analg. 1992. PMID: 1731547 Clinical Trial.
-
Comparison of plasma inorganic fluoride concentration with sevoflurane-N2O and enflurane-N2O anesthesia.Yonsei Med J. 1994 Jun;35(2):218-22. doi: 10.3349/ymj.1994.35.2.218. Yonsei Med J. 1994. PMID: 8091799
-
General anesthetic agents (what every surgeon should know about anesthesia, but has been afraid to ask).Otolaryngol Clin North Am. 1981 Aug;14(3):489-500. Otolaryngol Clin North Am. 1981. PMID: 7029407 Review. No abstract available.
-
Molecular and Integrative Physiological Effects of Isoflurane Anesthesia: The Paradigm of Cardiovascular Studies in Rodents using Magnetic Resonance Imaging.Front Cardiovasc Med. 2016 Jul 29;3:23. doi: 10.3389/fcvm.2016.00023. eCollection 2016. Front Cardiovasc Med. 2016. PMID: 27525256 Free PMC article. Review.
Cited by
-
Critical care pharmacotherapy. A review.Drugs. 1993 Mar;45(3):338-52. doi: 10.2165/00003495-199345030-00003. Drugs. 1993. PMID: 7682905 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources