Calcium-sensitive mini- and microelectrodes
- PMID: 23547145
- DOI: 10.1101/pdb.top066290
Calcium-sensitive mini- and microelectrodes
Abstract
It is widely agreed that the best method for measuring the ionized free calcium concentration ([Ca(2+)]) in large volumes of biological solutions is to use Ca(2+)-sensitive macroelectrodes. These are commercially available. To measure [Ca(2+)] in small volumes of solution, minielectrodes with 1-2-mm tips can easily be made and used, and may also be commercially available. Ca(2+)-sensitive microelectrodes (CaSMs, with 0.5-2-μm tips) can also be made and used extracellularly or intracellularly in robust cells, but interest in their use has recently been largely eclipsed. This is because of practical difficulties and the introduction of a large number of fluorescent and other optical calcium probes with calcium sensitivities varying from the nanomolar to the millimolar range, such as Fura-2, Indo-1, Fluo-4, and many others. In this article, we emphasize the utility of Ca(2+)-selective electrodes and show that their use is complementary to use of fluorescent and other optical methods. Each method has advantages and disadvantages. Because numerous reviews and books have been dedicated to the theoretical aspects of ion-selective electrode principles and technology, this article is mainly intended for investigators who have some degree of electrophysiological experience with ion-selective electrodes or microelectrodes.
Similar articles
-
Making and using calcium-selective mini- and microelectrodes.Methods Cell Biol. 2010;99:67-89. doi: 10.1016/B978-0-12-374841-6.00003-7. Methods Cell Biol. 2010. PMID: 21035683
-
How to make calcium-sensitive microelectrodes.Cold Spring Harb Protoc. 2013 Apr 1;2013(4):374-8. doi: 10.1101/pdb.prot072868. Cold Spring Harb Protoc. 2013. PMID: 23547154
-
How to make calcium-sensitive minielectrodes.Cold Spring Harb Protoc. 2013 Apr 1;2013(4):370-3. doi: 10.1101/pdb.prot072850. Cold Spring Harb Protoc. 2013. PMID: 23547153
-
How to make and use calcium-specific mini- and microelectrodes.Methods Cell Biol. 1994;40:93-113. Methods Cell Biol. 1994. PMID: 8201986 Review. No abstract available.
-
Measurement of cytosolic calcium: ion selective microelectrodes.Miner Electrolyte Metab. 1988;14(1):15-21. Miner Electrolyte Metab. 1988. PMID: 3279293 Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous