Real time three-dimensional echocardiography for quantification of ventricular volumes, mass, and function in children with congenital and acquired heart diseases
- PMID: 23551607
- DOI: 10.1111/echo.12132
Real time three-dimensional echocardiography for quantification of ventricular volumes, mass, and function in children with congenital and acquired heart diseases
Abstract
Quantitative measurement of left ventricular (LV) volumes, mass, and function is one of the most common and important indications for echocardiography. These measurements are among the most powerful tools for diagnosis and prognosis of congenital and acquired heart diseases and for assessment of medical, percutaneous, and surgical interventions. Awareness is also growing of the importance of right ventricular (RV) volume, mass, and function in many cardiopulmonary diseases. Furthermore, there are challenges and opportunities to measure the volume, mass, and function of complex chambers such as the left atrium, right atrium, and the univentricular heart. As echocardiography continues to be the imaging modality of choice for these measurements, the strengths and limitations of M-mode, two-dimensional (2D), and recently three-dimensional (3D) echocardiographic (3DE) methodologies for accurate and reproducible measurement of these indices have been extensively investigated for congenital and acquired heart diseases. Evidence suggests that 3DE provides improved accuracy and reproducibility over 2D methods for measurement of LV volume and function calculation in adults and in children. Data have accumulated on the utility of 3DE for measuring chamber volumes and function for the RV and for the single ventricle, which may become more widely used in clinical and research arenas in the future. Finally, new advanced modes of analysis such as 3D strain and synchrony analysis by 3DE are promising methodologies that warrant further investigation.
© 2013, Wiley Periodicals, Inc.
Similar articles
-
How accurately, reproducibly, and efficiently can we measure left ventricular indices using M-mode, 2-dimensional, and 3-dimensional echocardiography in children?Am Heart J. 2008 May;155(5):946-53. doi: 10.1016/j.ahj.2007.11.034. Epub 2008 Feb 21. Am Heart J. 2008. PMID: 18440346
-
Three-dimensional echocardiographic evaluation of right ventricular volume and function in pediatric patients: validation of the technique.J Am Soc Echocardiogr. 2007 Aug;20(8):921-9. doi: 10.1016/j.echo.2007.01.018. Epub 2007 Jun 6. J Am Soc Echocardiogr. 2007. PMID: 17555933
-
Feasibility of three-dimensional transthoracic echocardiography to evaluate right ventricular volumes in children and comparison to left ventricular values.Echocardiography. 2012 Apr;29(4):492-501. doi: 10.1111/j.1540-8175.2011.01596.x. Epub 2011 Dec 9. Echocardiography. 2012. PMID: 22150697
-
Evolving Role of Three-Dimensional Echocardiography for Right Ventricular Volume Analysis in Pediatric Heart Disease: Literature Review and Clinical Applications.J Am Soc Echocardiogr. 2024 Jun;37(6):634-640. doi: 10.1016/j.echo.2024.03.001. Epub 2024 Mar 11. J Am Soc Echocardiogr. 2024. PMID: 38467312 Review.
-
[Current clinical applications of three-dimensional echocardiography].G Ital Cardiol (Rome). 2019 Dec;20(12):722-735. doi: 10.1714/3271.32381. G Ital Cardiol (Rome). 2019. PMID: 31834296 Review. Italian.
Cited by
-
Accuracy of the ClearSight™ system in patients undergoing abdominal aortic aneurysm surgery.J Anesth. 2019 Jun;33(3):364-371. doi: 10.1007/s00540-019-02632-6. Epub 2019 Mar 23. J Anesth. 2019. PMID: 30904953
-
Usefulness of three-dimensional echocardiography for the assessment of ventricular function in children: Comparison with cardiac magnetic resonance, with a focus on patients with arrhythmia.Cardiol J. 2021;28(4):549-557. doi: 10.5603/CJ.a2019.0026. Epub 2019 Mar 26. Cardiol J. 2021. PMID: 30912575 Free PMC article.
-
Innovation in 3D Echocardiographic Imaging.Curr Treat Options Cardiovasc Med. 2018 Jan 19;20(1):1. doi: 10.1007/s11936-018-0598-y. Curr Treat Options Cardiovasc Med. 2018. PMID: 29349638 Review.
-
Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.J Anesth. 2018 Jun;32(3):387-393. doi: 10.1007/s00540-018-2491-y. Epub 2018 Apr 3. J Anesth. 2018. PMID: 29616345
-
A study of the clinical application value of ultrasound and electrocardiogram in the differential diagnosis of cardiomyopathy.Am J Transl Res. 2021 May 15;13(5):5200-5207. eCollection 2021. Am J Transl Res. 2021. PMID: 34150109 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials