Case Reports
. 2013 Nov;110(11):1066-8.
doi: 10.1007/s00347-013-2793-2.

[Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber]

[Article in German]
Affiliations
Case Reports

[Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber]

[Article in German]
G Schmidinger et al. Ophthalmologe. 2013 Nov.

Abstract

A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

PubMed Disclaimer

References

    1. Eur J Ophthalmol. 2006 Sep-Oct;16(5):758-60 - PubMed
    1. Am J Ophthalmol. 2012 Jun;153(6):1082-90.e2 - PubMed
    1. Ophthalmologe. 2012 May;109(5):483-6 - PubMed
    1. J Cataract Refract Surg. 2008 Sep;34(9):1584-91 - PubMed
    1. Am J Ophthalmol. 2012 Jun;153(6):1154-60.e1 - PubMed

LinkOut - more resources