Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2013 Jul;37(7):1618-25.
doi: 10.1007/s00268-013-2021-x.

Three-dimensional metabolic and radiologic gathered evaluation using VR-RENDER fusion: a novel tool to enhance accuracy in the localization of parathyroid adenomas

Affiliations
Observational Study

Three-dimensional metabolic and radiologic gathered evaluation using VR-RENDER fusion: a novel tool to enhance accuracy in the localization of parathyroid adenomas

Jacopo D'Agostino et al. World J Surg. 2013 Jul.

Abstract

Background: The aim of this study was to assess the accuracy of a novel imaging modality, three-dimensional (3D) metabolic and radiologic gathered evaluation (MeRGE), for localizing parathyroid adenomas (PAs).

Methods: Consecutive patients presenting with primary hyperparathyroidism who underwent both thin-slice cervical computed tomography (CT) and (99m)Tc-sestamibi (MIBI) scanning were included. 3D-CT reconstruction was obtained using VR-RENDER, which was used to perform 3D virtual neck exploration (3D-VNE). The MIBI scan was then fused with the 3D reconstruction to obtain 3D-MeRGE. Sensitivity, specificity, and accuracy were assessed. Parathyroid gland volume and preoperative parathormone (PTH) levels were analyzed as predictive factors of correct localization (i.e., correct quadrant).

Results: A total of 108 cervical quadrants (27 patients) were analyzed. Sensitivities were 79.31, 75.86, 65.51, and 58.61 % with 3D-MeRGE, 3D-VNE, MIBI, and CT, respectively. Specificity was highest with CT (94.93 %) followed by 3D-VNE (92.4 %). MIBI and 3D-MeRGE had the same specificity (88.6 %). 3D-MeRGE and 3D-VNE achieved higher accuracy than MIBI or CT alone. Mean PTH values were significantly higher in patients with lesions that were correctly identified (true positive, TP) than in those whose lesions were missed (false negative, FN) with 3D-VNE (219.60 ± 212.77 vs. 98.75 ± 12.76 pg/ml; p = 0.01) and 3D-MeRGE (217.69 ± 213.76 vs. 09.75 ± 20.48 pg/ml; p = 0.02). The mean parathyroid gland volume difference between TP and FN was statistically significant with all modalities except CT.

Conclusions: 3D-MeRGE and 3D-VNE showed high accuracy for localization of PAs. 3D-MeRGE performed better than MIBI or CT alone for detecting small adenomas and those with a low PTH level.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Surgery. 2010 Dec;148(6):1129-37; discussion 1137-8 - PubMed
    1. Langenbecks Arch Surg. 2009 Sep;394(5):765-84 - PubMed
    1. N Engl J Med. 2007 Nov 29;357(22):2277-84 - PubMed
    1. Arch Surg. 2005 May;140(5):472-8; discussion 478-9 - PubMed
    1. Surgery. 2003 Dec;134(6):973-9; discussion 979-81 - PubMed

Publication types

MeSH terms

Substances