Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2013 Jun;39(6):1034-9.
doi: 10.1007/s00134-013-2888-x. Epub 2013 Apr 5.

Central venous-arterial pCO₂ difference as a tool in resuscitation of septic patients

Affiliations
Multicenter Study

Central venous-arterial pCO₂ difference as a tool in resuscitation of septic patients

Paul A van Beest et al. Intensive Care Med. 2013 Jun.

Abstract

Purpose: To investigate the interchangeability of mixed and central venous-arterial carbon dioxide differences and the relation between the central difference (pCO₂ gap) and cardiac index (CI). We also investigated the value of the pCO₂ gap in outcome prediction.

Methods: We performed a post hoc analysis of a well-defined population of 53 patients with severe sepsis or septic shock. Mixed and central venous pCO₂ were determined earlier at a 6 h interval (T = 0 to T = 4) during the first 24 h after intensive care unit (ICU) admittance. The population was divided into two groups based on pCO₂ gap (cut off value 0.8 kPa).

Results: The mixed pCO₂ difference underestimated the central pCO₂ difference by a mean bias of 0.03 ± 0.32 kPa (95 % limits of agreement: -0.62-0.58 kPa). We observed a weak relation between pCO₂ gap and CI. The in hospital mortality rate was 21 % (6/29) for the low gap group and 29 % (7/24) for the high gap group; the odds ratio was 1.6 (95 % CI 0.5-5.5), p = 0.53. At T = 4 the odds ratio was 5.3 (95 % CI 0.9-30.7); p = 0.08.

Conclusions: From a practical perspective, the clinical utility of central venous pCO₂ values is of potential interest in determining the venous-arterial pCO₂ difference. The likelihood of a bad outcome seems to be enhanced when a high pCO₂ gap persists after 24 h of therapy.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Intensive Care Med. 2005 Jun;31(6):818-22 - PubMed
    1. N Engl J Med. 1995 Oct 19;333(16):1025-32 - PubMed
    1. Chest. 1992 Feb;101(2):509-15 - PubMed
    1. Crit Care. 2010;14(6):R219 - PubMed
    1. Crit Care. 2008;12(2):R33 - PubMed

Publication types

LinkOut - more resources