Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 May 15;163(2-3):218-22.
doi: 10.1016/j.ijfoodmicro.2013.03.007. Epub 2013 Mar 21.

Repeated detection of microbes in beverages dispensed from soda fountain machines and the effect of flushing on microbial density

Affiliations

Repeated detection of microbes in beverages dispensed from soda fountain machines and the effect of flushing on microbial density

Renee D Godard et al. Int J Food Microbiol. .

Abstract

Few studies have examined patterns of microbial contamination in soda fountain beverages. In this study, patterns of microbial contamination in beverages dispensed from soda fountain machines (SFMs) sampled in June 2009 and then again 13 months later were compared. Over 70% of beverages contained microbes in both years, suggesting that contamination of beverages dispensed from SFMs can continue for long periods of time. In addition, the impact of disinfecting the dispensing nozzles and plastic tubing of SFMs, as well as the impact of machine use on microbial contamination was assessed. Managers from 26 establishments (fast-food and convenience stores) were interviewed about their SFM disinfecting practices and no correlation was found between the self-reported disinfecting practices and levels of microbial contamination in beverages dispensed from SFMs. Furthermore, in a direct study of two SFMs with an established disinfecting regimen, CFU/mL in beverages increased significantly immediately after disinfecting of plastic tubing yet returned to pre-disinfecting concentrations within 11 days. These results suggest that disinfecting may disturb microbial communities, resulting in increased planktonic microbes, but not the ultimate removal of communities themselves. Additionally, samples of a sugar and a diet soda were collected from 15 different SFMs before and after dispensing of ~0.95 L (the approximate size of a large beverage cup). Samples collected before dispensing this volume had significantly higher microbial counts than those collected after, suggesting that planktonic microbes in the beverage lines had been reduced by flushing. As there are currently no regulations regarding the disinfecting of SFM tubing or periodic inspections of beverages dispensed from SFMs, it would be valuable for consumers to encourage increased surveillance of SFMs, and to dispense some beverage before filling their cups.

PubMed Disclaimer

Publication types

LinkOut - more resources