Open inguinal hernia repair with the use of polyglycolic acid/trimethylene carbonate mesh: gross and pathologic assessment of the inguinal area at reoperation for recurrence
- PMID: 23563733
- DOI: 10.1007/s10029-013-1079-6
Open inguinal hernia repair with the use of polyglycolic acid/trimethylene carbonate mesh: gross and pathologic assessment of the inguinal area at reoperation for recurrence
Abstract
Purpose: Our group tried to test the hypothesis of using a totally absorbable material for open inguinal hernia repair. However, the increased incidence of recurrences alleviated our initial enthusiasm regarding the technique. The purpose of the present study was to attain both gross and microscopic data that could at least in part justify the hernia repair failure from a patient included in our initial pilot study and was re-operated for recurrence.
Methods: A 65-year-old male patient was diagnosed clinically with a recurrence 24 months after open inguinal hernia repair with the use of polyglycolic acid/trimethylene carbonate mesh. The patient was operated for the recurrence upon our group on July 2012. The gross appearance of the inguinal area as well as the degree of chronic inflammation provoked by the used mesh as depicted by the pathologic analysis of specimens obtained intraoperatively were assessed.
Results: An open tension-free repair with the use of a non-absorbable mesh under spinal anesthetic was undertaken. Intraoperatively, after the division of the external oblique aponeurosis, only minor fibrotic reaction was observed a finding that was additionally confirmed pathologically.
Conclusion: Polyglycolic acid/trimethylene carbonate mesh used for inguinal hernia repair was associated with a minimal inflammatory host reaction in the inguinal area at 3 years verified both grossly and microscopically.
Similar articles
-
Open inguinal hernia repair with the use of a polyglycolic acid-trimethylene carbonate absorbable mesh: a pilot study.Hernia. 2011 Apr;15(2):181-4. doi: 10.1007/s10029-010-0765-x. Epub 2010 Dec 22. Hernia. 2011. PMID: 21181217
-
Open inguinal hernia repair with the use of polyglycolic acid/trimethylene carbonate absorbable mesh: a critical update of the long-term results.Hernia. 2013 Feb;17(1):85-7. doi: 10.1007/s10029-012-1016-0. Epub 2012 Nov 9. Hernia. 2013. PMID: 23138860
-
Chronic pain and risk for reoperation for recurrence after inguinal hernia repair using self-gripping mesh.Surgery. 2020 Mar;167(3):609-613. doi: 10.1016/j.surg.2019.11.011. Epub 2019 Dec 12. Surgery. 2020. PMID: 31839191
-
Lightweight mesh is recommended in open inguinal (Lichtenstein) hernia repair: A systematic review and meta-analysis.Surgery. 2020 Mar;167(3):581-589. doi: 10.1016/j.surg.2019.08.021. Epub 2019 Oct 28. Surgery. 2020. PMID: 31672519
-
Causes of recurrences after open inguinal herniorrhaphy.Hernia. 2019 Aug;23(4):637-645. doi: 10.1007/s10029-018-1868-z. Epub 2018 Dec 5. Hernia. 2019. PMID: 30519909 Review.
Cited by
-
Is it really worth it? Reply to: Selective use of bioabsorbable Gore BIO-A plug and patch for groin hernia repair. Negro P, Campanelli G, Ipponi PL, Gossetti F, Dassatti MR, Manto O, D'Amore L. Hernia. 2013, 17(6):795-6.Hernia. 2015 Jun;19(3):533-4. doi: 10.1007/s10029-014-1284-y. Epub 2014 Jul 29. Hernia. 2015. PMID: 25070173 No abstract available.
-
Surgical mesh for ventral incisional hernia repairs: Understanding mesh design.Plast Surg (Oakv). 2016 Spring;24(1):41-50. doi: 10.4172/plastic-surgery.1000955. Plast Surg (Oakv). 2016. PMID: 27054138 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources